Enhancing the Separation and Quantification of Perfluoroalkyl Substances Using Polymeric Ionic Liquid Sorbents in Thin Film Microextraction

The preconcentration and isolation of per- and polyfluoroalkyl substances (PFAS) remain challenging due to their varying chain lengths and diverse headgroup chemical functionalities. These substances are persistent and occur in the environment at low parts-per-trillion concentration levels, necessitating the use of efficient and selective sorbents that can enhance their preconcentration from the targeted sample prior to instrumental analysis. This study, for the first time, evaluates the use of a polymeric ionic liquid (PIL) consisting of 1-(9-carboxy-nonyl)-3-vinylimidazolium bromide [C<sub>9</sub>COOHVim<sup>+</sup>] [Br<sup>-</sup>] ionic liquid (IL) monomer and 1,12-di(3-vinylimidazolium)dodecane bromide ([C<sub>12</sub>(Vim<sup>+</sup>)<sub>2</sub>]2[Br<sup>-</sup>]) IL cross-linker for the simultaneous separation and preconcentration of 15 anionic PFAS. The PIL was immobilized on a thin film microextraction device to improve preconcentration, extraction, and desorption kinetics. The addition of competing anions to the desorption solution was critical to ensure the quantitative desorption of the anionic PFAS by an ion exchange mechanism. Partition coefficient calculations revealed a balanced extraction coverage for short- and long-chain PFAS in ultrapure water, while in solutions at high ionic strength, short-chain PFAS tend to display less affinity for the sorbent compared to long-chain PFAS. Kinetic studies showed that less hydrophobic PFAS (perfluorobutanoic acid (PFBA)-perfluorohexanoic acid (PFHxA)) reached equilibrium faster and the extraction followed a pseudo-second order model with <i>r</i><sup>2</sup> values up to 0.9874. The applicability of the PIL-thin film microextraction (TFME) device for quantitative analysis was demonstrated by a calibration curve in a concentration range from 1 ng L<sup>-1</sup> to 2500 ng L<sup>-1</sup>, which showed good accuracy (70-130%), precision (<20%), and limits of quantification from 1 ng L<sup>-1</sup> to 50 ng L<sup>-1</sup>.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-04-07
DOI
https://doi.org/10.1021/acs.analchem.4c06522
Citations
1
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
0.86

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing the Separation and Quantification of Perfluoroalkyl Substances Using Polymeric Ionic Liquid Sorbents in Thin Film Microextraction

Aghogho A. Olomukoro, Emanuela Gionfriddo, Derek R. Eitzmann, Jared L. Anderson
1 citations
Analytical Chemistry
Per- and polyfluoroalkyl substances research
0.86
article

Enhancing the Separation and Quantification of Perfluoroalkyl Substances Using Polymeric Ionic Liquid Sorbents in Thin Film Microextraction

Aghogho A. Olomukoro, Emanuela Gionfriddo, Derek R. Eitzmann, Jared L. Anderson
article en
1 citations

Abstract

The preconcentration and isolation of per- and polyfluoroalkyl substances (PFAS) remain challenging due to their varying chain lengths and diverse headgroup chemical functionalities. These substances are persistent and occur in the environment at low parts-per-trillion concentration levels, necessitating the use of efficient and selective sorbents that can enhance their preconcentration from the targeted sample prior to instrumental analysis. This study, for the first time, evaluates the use of a polymeric ionic liquid (PIL) consisting of 1-(9-carboxy-nonyl)-3-vinylimidazolium bromide [C<sub>9</sub>COOHVim<sup>+</sup>] [Br<sup>-</sup>] ionic liquid (IL) monomer and 1,12-di(3-vinylimidazolium)dodecane bromide ([C<sub>12</sub>(Vim<sup>+</sup>)<sub>2</sub>]2[Br<sup>-</sup>]) IL cross-linker for the simultaneous separation and preconcentration of 15 anionic PFAS. The PIL was immobilized on a thin film microextraction device to improve preconcentration, extraction, and desorption kinetics. The addition of competing anions to the desorption solution was critical to ensure the quantitative desorption of the anionic PFAS by an ion exchange mechanism. Partition coefficient calculations revealed a balanced extraction coverage for short- and long-chain PFAS in ultrapure water, while in solutions at high ionic strength, short-chain PFAS tend to display less affinity for the sorbent compared to long-chain PFAS. Kinetic studies showed that less hydrophobic PFAS (perfluorobutanoic acid (PFBA)-perfluorohexanoic acid (PFHxA)) reached equilibrium faster and the extraction followed a pseudo-second order model with <i>r</i><sup>2</sup> values up to 0.9874. The applicability of the PIL-thin film microextraction (TFME) device for quantitative analysis was demonstrated by a calibration curve in a concentration range from 1 ng L<sup>-1</sup> to 2500 ng L<sup>-1</sup>, which showed good accuracy (70-130%), precision (<20%), and limits of quantification from 1 ng L<sup>-1</sup> to 50 ng L<sup>-1</sup>.

Analytical ChemistryVol. 97(14)
Iowa State University (US), University at Buffalo, State University of New York (US), University of Toledo (US)
Iowa State University, Division of Chemistry
Openalex Percentile: Top 29%
Per- and polyfluoroalkyl substances research
0.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.