Effects of Corona Discharge from the Grounding Tip on Charge Evolution of Wall Bushing

Manufacturers consider that the grounding tip near the wall bushing flange is a potentially important factor in several sheath perforation accidents. Taking a ±100 kV true type SF<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> gas-insulated bushing as a typical wall bushing, this paper tests the impact of the nearby grounding tip on the charge accumulation. Based on the experiment results, we propose the three-dimensional nonlinear conduction model to unravel the charge accumulation process and the three-dimensional corona ion migration model to clarify the corona process. It is concluded that the consumption of gas ions leads to the nonlinear charge relaxation process. When the corona of grounding tip incepts, numerous ions are generated, forming an “overcharge” phenomenon. The electric field at the insulator-sheds interface and the SF<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub>-insulator interface increases compared to the normal condition, with non-uniform distribution along the circumferential direction. Material inhomogeneity amplifies electric field distortion and creates insulation weaknesses, making insulation aging more likely and potentially leading to a slowly developing electrical tree breakdown process. The length of the needle tip affects the duration of the corona effect; an excessively long needle tip can cause a sustained corona discharge. This research provides a foundation for bushing accidents analysis and operation reliability improvement.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Delivery
Published
2025-04-07
DOI
https://doi.org/10.1109/tpwrd.2025.3556924
Citations
1
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Corona Discharge from the Grounding Tip on Charge Evolution of Wall Bushing

Taiwei Liu, Xiongjie Xie, Xin Huang, Yunxiao Zhang et al.
1 citations
IEEE Transactions on Power Delivery
High voltage insulation and dielectric phenomena
0.52
article

Effects of Corona Discharge from the Grounding Tip on Charge Evolution of Wall Bushing

Taiwei Liu, Xiongjie Xie, Xin Huang, Yunxiao Zhang, Yuanxiang Zhou, Zheng Feng Bai
article en
1 citations

Abstract

Manufacturers consider that the grounding tip near the wall bushing flange is a potentially important factor in several sheath perforation accidents. Taking a ±100 kV true type SF<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> gas-insulated bushing as a typical wall bushing, this paper tests the impact of the nearby grounding tip on the charge accumulation. Based on the experiment results, we propose the three-dimensional nonlinear conduction model to unravel the charge accumulation process and the three-dimensional corona ion migration model to clarify the corona process. It is concluded that the consumption of gas ions leads to the nonlinear charge relaxation process. When the corona of grounding tip incepts, numerous ions are generated, forming an “overcharge” phenomenon. The electric field at the insulator-sheds interface and the SF<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub>-insulator interface increases compared to the normal condition, with non-uniform distribution along the circumferential direction. Material inhomogeneity amplifies electric field distortion and creates insulation weaknesses, making insulation aging more likely and potentially leading to a slowly developing electrical tree breakdown process. The length of the needle tip affects the duration of the corona effect; an excessively long needle tip can cause a sustained corona discharge. This research provides a foundation for bushing accidents analysis and operation reliability improvement.

IEEE Transactions on Power DeliveryVol. 40(3)
China Electric Power Research Institute, Tsinghua University (CN)
Life in Land
Openalex Percentile: Top 40%
High voltage insulation and dielectric phenomena
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effects of Corona Discharge from the Grounding Tip on Charge Evolution of Wall Bushing — Taiwei Liu, Xiongjie Xie, et al. · IEEE Transactions on Power Delivery (2025) | TGRS Research Map | TGRS