Noise Perception, Sensitivity, and Patient Outcomes During Cesarean Delivery

<b>Introduction:</b> Noise in the operating room (OR) is a recognized hazard, known to impair communication among staff and increase stress levels. While its effects on healthcare personnel have been studied, little is known about patient perception of noise, particularly during cesarean delivery (CD) under neuraxial anesthesia, where patients are fully conscious. This study aimed to investigate if patients undergoing CD perceive OR noise as stressful and to examine the correlation between actual noise levels and patient-reported stress. <b>Methods:</b> This prospective observational study was conducted on women undergoing CD at the University of Iowa Hospitals and Clinics. Eligible participants had sound levels recorded in the two ORs and completed three questionnaires 24 h postsurgery: the Weinstein Noise Sensitivity Questionnaire Short Form (WNSSF), a noise perception questionnaire, and a noise-related stress questionnaire. Noise levels were measured using a Spartan model 730 noise dosimeter, and the study analyzed the correlation between noise sensitivity, perception, and stress, as well as the effect of surgery urgency on noise levels. <b>Results:</b> Out of 70 participants, 67 were included in the final analysis. The ambient noise levels in the ORs were 53.4 and 58.5 dB, respectively. The mean noise sensitivity score was 17.6 (±3.9). Noise was perceived as very soft or soft by 23% of patients, comfortable by 67.8%, and loud or unpleasant by 9.2%. A significant association was found between noise sensitivity and stress (OR 1.15 [95 CI 1.03-1.31], <i>p</i>=0.038). <b>Conclusions:</b> The study found that a subset of patients experienced noise-related stress during CD, particularly those with higher noise sensitivity. These findings suggest the need for interventions to reduce OR noise or manage patient perceptions of noise.

Authors

Institutions

Publication Details

Journal
Anesthesiology Research and Practice
Published
2025-01-01
DOI
https://doi.org/10.1155/anrp/5707084
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noise Perception, Sensitivity, and Patient Outcomes During Cesarean Delivery

Unyime S. Ituk, Erik Anderson, Carl M Skoog, Michelle N. Bremer Gama
Anesthesiology Research and Practice
Noise Effects and Management
article

Noise Perception, Sensitivity, and Patient Outcomes During Cesarean Delivery

Unyime S. Ituk, Erik Anderson, Carl M Skoog, Michelle N. Bremer Gama
article en

Abstract

<b>Introduction:</b> Noise in the operating room (OR) is a recognized hazard, known to impair communication among staff and increase stress levels. While its effects on healthcare personnel have been studied, little is known about patient perception of noise, particularly during cesarean delivery (CD) under neuraxial anesthesia, where patients are fully conscious. This study aimed to investigate if patients undergoing CD perceive OR noise as stressful and to examine the correlation between actual noise levels and patient-reported stress. <b>Methods:</b> This prospective observational study was conducted on women undergoing CD at the University of Iowa Hospitals and Clinics. Eligible participants had sound levels recorded in the two ORs and completed three questionnaires 24 h postsurgery: the Weinstein Noise Sensitivity Questionnaire Short Form (WNSSF), a noise perception questionnaire, and a noise-related stress questionnaire. Noise levels were measured using a Spartan model 730 noise dosimeter, and the study analyzed the correlation between noise sensitivity, perception, and stress, as well as the effect of surgery urgency on noise levels. <b>Results:</b> Out of 70 participants, 67 were included in the final analysis. The ambient noise levels in the ORs were 53.4 and 58.5 dB, respectively. The mean noise sensitivity score was 17.6 (±3.9). Noise was perceived as very soft or soft by 23% of patients, comfortable by 67.8%, and loud or unpleasant by 9.2%. A significant association was found between noise sensitivity and stress (OR 1.15 [95 CI 1.03-1.31], <i>p</i>=0.038). <b>Conclusions:</b> The study found that a subset of patients experienced noise-related stress during CD, particularly those with higher noise sensitivity. These findings suggest the need for interventions to reduce OR noise or manage patient perceptions of noise.

Anesthesiology Research and PracticeVol. 2025(1)
University of Iowa (US), University of Minnesota (US), Iowa Methodist Medical Center (US)
Openalex Percentile: Top 91%
Noise Effects and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.