Behaviour of screw shear connections between oriented strand board and cold-formed steel sections under ambient and post-heating conditions: An experimental and analytical investigation

This paper presents an experimental and numerical investigation of the push-out behaviour of shear connectors in oriented strand board (OSB) and cold-formed steel (CFS) composite beams under ambient and post-heating conditions. The results of this research are used to evaluate the level of accuracy of existing Eurocode 5 design equations for the prediction of failure mode and failure load of shear connectors for ambient temperature design and for post-fire assessment. Ambient temperature and uniform temperature post-heating tests were carried out on OSB material under compression and on OSB-steel shear connectors under push-out loading. The compressive mechanical tests were used to obtain residual mechanical properties of OSB after heating to different temperatures, and to provide shear connector behaviour for the assessment of the Eurocode 5 design method and for validation of a numerical simulation model. The 16 push-out tests comprised two temperatures (ambient & 200 °C), two screw diameters (3.5 mm & 5.5 mm), and two steel section thicknesses (1.2 mm & 2.4 mm). It has been found that the existing Eurocode 5 design method is particularly inaccurate in predicting the bearing resistance of shear connectors with thin-steel plates. The Eurocode 5 method of using a fixed value of 0.25 to account for inclination of the steel screw was also found to be inaccurate. Through a systematic numerical parametric study , modifications have been proposed to improve the Eurocode calculation method. The revised method was found to provide greatly improved predictions of the new test results of this research for both ambient and uniform post-heating tests and previous test results by others at ambient temperature. • First reported experimental work on post-heated screw shear connectors for composite beam between OSB-steel section. • Detailed evaluation of Eurocode 5 design method for load resistance of screwed shear connection between OSB-steel section. • Systematic analysis based on comprehensive experimental, numerical and analytical investigations. • Proposals for improved design method for ambient and post-heating applications.

Authors

Institutions

Publication Details

Journal
Engineering Structures
Published
2025-04-07
DOI
https://doi.org/10.1016/j.engstruct.2025.120209
Citations
2
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
1.91
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Behaviour of screw shear connections between oriented strand board and cold-formed steel sections under ambient and post-heating conditions: An experimental and analytical investigation

Zheng Feng, Lee S. Cunningham, Yong Wang
2 citations
Engineering Structures
Structural Load-Bearing Analysis
1.91
article

Behaviour of screw shear connections between oriented strand board and cold-formed steel sections under ambient and post-heating conditions: An experimental and analytical investigation

Zheng Feng, Lee S. Cunningham, Yong Wang
article en
2 citations

Abstract

This paper presents an experimental and numerical investigation of the push-out behaviour of shear connectors in oriented strand board (OSB) and cold-formed steel (CFS) composite beams under ambient and post-heating conditions. The results of this research are used to evaluate the level of accuracy of existing Eurocode 5 design equations for the prediction of failure mode and failure load of shear connectors for ambient temperature design and for post-fire assessment. Ambient temperature and uniform temperature post-heating tests were carried out on OSB material under compression and on OSB-steel shear connectors under push-out loading. The compressive mechanical tests were used to obtain residual mechanical properties of OSB after heating to different temperatures, and to provide shear connector behaviour for the assessment of the Eurocode 5 design method and for validation of a numerical simulation model. The 16 push-out tests comprised two temperatures (ambient & 200 °C), two screw diameters (3.5 mm & 5.5 mm), and two steel section thicknesses (1.2 mm & 2.4 mm). It has been found that the existing Eurocode 5 design method is particularly inaccurate in predicting the bearing resistance of shear connectors with thin-steel plates. The Eurocode 5 method of using a fixed value of 0.25 to account for inclination of the steel screw was also found to be inaccurate. Through a systematic numerical parametric study , modifications have been proposed to improve the Eurocode calculation method. The revised method was found to provide greatly improved predictions of the new test results of this research for both ambient and uniform post-heating tests and previous test results by others at ambient temperature. • First reported experimental work on post-heated screw shear connectors for composite beam between OSB-steel section. • Detailed evaluation of Eurocode 5 design method for load resistance of screwed shear connection between OSB-steel section. • Systematic analysis based on comprehensive experimental, numerical and analytical investigations. • Proposals for improved design method for ambient and post-heating applications.

Engineering StructuresVol. 334
University of Manchester (GB)
Openalex Percentile: Top 16%
Structural Load-Bearing Analysis
1.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.