AC Losses Analysis on a Twisted Stacked-Tape Cable With Stepped Grooves

This paper mainly shares an ac loss numerical study of a stacked YBCO cable with stepped grooves in 77 K. The model divided YBCO tapes to three layers to balance accuracy and efficiency. AC loss contributions and eddy current losses are estimated in detail at various magnetic fields and frequencies. A conventional configuration of TSTC is researched for comparison. With the same number of tapes, the stepped-slot structure is less affected by the magnetic field, resulting in a higher critical current and lower AC loss compared to the traditional structure. When the current frequency is varied, the stepped-slot structure cable also exhibits lower AC losses. The AC losses in the superconducting layer are greater than the eddy current losses, which is in contrast to the traditional structure where the eddy current losses far exceeds the AC losses. As for the study on tape configuration, a more balanced distribution of tapes between the two slots in the stepped-slot structure leads to a reduction in both the external field and frequency dependence, thereby improving the AC losses performance

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Applied Superconductivity
Published
2025-04-07
DOI
https://doi.org/10.1109/tasc.2025.3558431
Primary Topic
Mechanical stress and fatigue analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AC Losses Analysis on a Twisted Stacked-Tape Cable With Stepped Grooves

Peng Yu, Zhonghang Li, Junfeng Yang, Tao Ma et al.
3 links
IEEE Transactions on Applied Superconductivity
Mechanical stress and fatigue analysis
article

AC Losses Analysis on a Twisted Stacked-Tape Cable With Stepped Grooves

Peng Yu, Zhonghang Li, Junfeng Yang, Tao Ma, Yifeng Li
article en

Abstract

This paper mainly shares an ac loss numerical study of a stacked YBCO cable with stepped grooves in 77 K. The model divided YBCO tapes to three layers to balance accuracy and efficiency. AC loss contributions and eddy current losses are estimated in detail at various magnetic fields and frequencies. A conventional configuration of TSTC is researched for comparison. With the same number of tapes, the stepped-slot structure is less affected by the magnetic field, resulting in a higher critical current and lower AC loss compared to the traditional structure. When the current frequency is varied, the stepped-slot structure cable also exhibits lower AC losses. The AC losses in the superconducting layer are greater than the eddy current losses, which is in contrast to the traditional structure where the eddy current losses far exceeds the AC losses. As for the study on tape configuration, a more balanced distribution of tapes between the two slots in the stepped-slot structure leads to a reduction in both the external field and frequency dependence, thereby improving the AC losses performance

IEEE Transactions on Applied SuperconductivityVol. 35(4)
Beijing Jiaotong University (CN), Shenzhen Stock Exchange (CN)
Openalex Percentile: Top 92%
Mechanical stress and fatigue analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

AC Losses Analysis on a Twisted Stacked-Tape Cable With Stepped Grooves — Peng Yu, Zhonghang Li, et al. · IEEE Transactions on Applied Superconductivity (2025) | TGRS Research Map | TGRS