Design and Validation of a Cable-Driven Joint Actuator for Pediatric Knee Orthoses

Robot-assisted gait rehabilitation is an increasingly common therapeutic intervention for enhancing locomotion and improving quality of life for children with lower-limb mobility impairments. However, there are few systems specifically designed for pediatric use, and those that do exist are largely cumbersome, bulky, and noncustom devices that ultimately reduce therapy effectiveness. This paper introduces the Cable-Driven Joint System (CDJS), a novel approach for pediatric gait rehabilitation that addresses these shortcomings in a lightweight and compact robotic device using the patient's professionally fitted orthosis. The CDJS consists of a 2.1 kg actuation unit that is held by a clinician which delivers assistive torques through a Bowden cable transmission to a 0.3 kg joint mounted to user-custom bracing. This work details an actuator benchtop evaluation, demonstrating a peak torque of 20 N·m, peak velocity of 7.2 rad/s, bandwidth of 9.7 Hz, and a mass moment of inertia of 58.38 kg cm2. An actuator model was developed and evaluated in simulation, showing a strong correlation with the experimental torque data (R-squared = 0.95) and indicating a transmission efficiency of 72%. In-air gait tracking experiments on an emulated subject showed that the CDJS assisted the subject to track a nominal knee trajectory with an average root-mean-squared error of 2.56 deg at a continuous torque of 1.37 N·m. These results suggest that the cable-driven actuator meets the design requirements for use in pediatric gait rehabilitation and is ready for implementation in clinical device trials.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanical Engineering
Published
2025-04-07
DOI
https://doi.org/10.1115/1.4068369
Citations
1
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Validation of a Cable-Driven Joint Actuator for Pediatric Knee Orthoses

Jerzy T. Sawicki, Ryan J. Farris, Jason Wiebrecht, Jacob A. Strick
1 citations
Journal of Biomechanical Engineering
Prosthetics and Rehabilitation Robotics
0.67
article

Design and Validation of a Cable-Driven Joint Actuator for Pediatric Knee Orthoses

Jerzy T. Sawicki, Ryan J. Farris, Jason Wiebrecht, Jacob A. Strick
article en
1 citations

Abstract

Robot-assisted gait rehabilitation is an increasingly common therapeutic intervention for enhancing locomotion and improving quality of life for children with lower-limb mobility impairments. However, there are few systems specifically designed for pediatric use, and those that do exist are largely cumbersome, bulky, and noncustom devices that ultimately reduce therapy effectiveness. This paper introduces the Cable-Driven Joint System (CDJS), a novel approach for pediatric gait rehabilitation that addresses these shortcomings in a lightweight and compact robotic device using the patient's professionally fitted orthosis. The CDJS consists of a 2.1 kg actuation unit that is held by a clinician which delivers assistive torques through a Bowden cable transmission to a 0.3 kg joint mounted to user-custom bracing. This work details an actuator benchtop evaluation, demonstrating a peak torque of 20 N·m, peak velocity of 7.2 rad/s, bandwidth of 9.7 Hz, and a mass moment of inertia of 58.38 kg cm2. An actuator model was developed and evaluated in simulation, showing a strong correlation with the experimental torque data (R-squared = 0.95) and indicating a transmission efficiency of 72%. In-air gait tracking experiments on an emulated subject showed that the CDJS assisted the subject to track a nominal knee trajectory with an average root-mean-squared error of 2.56 deg at a continuous torque of 1.37 N·m. These results suggest that the cable-driven actuator meets the design requirements for use in pediatric gait rehabilitation and is ready for implementation in clinical device trials.

Journal of Biomechanical EngineeringVol. 147(6)
Cleveland State University (US), Messiah University (US)
Openalex Percentile: Top 33%
Prosthetics and Rehabilitation Robotics
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and Validation of a Cable-Driven Joint Actuator for Pediatric Knee Orthoses — Jerzy T. Sawicki, Ryan J. Farris, et al. · Journal of Biomechanical Engineering (2025) | TGRS Research Map | TGRS