AI-based spectral metal artifact reduction algorithm for improved iodine detection in virtual monoenergetic images: a quantitative assessment for interventional oncology applications

In this work, we developed a deep CNN based spectral metal artifact reduction algorithm for interventional oncology applications (sMARIO) and quantitatively assessed its performance pertaining to iodine contrast detectability. CNN models were trained specifically for each basis images for spectral CT using patient data with the virtual insertion of metallic probes. Two solid rods (2.5 cm in diameter) representing water and 2mgI/ml iodinated solution, respectively, were inserted in a anthropomorphic phantom and scanned on a spectral CT scanner in both presence and absence of metallic probes used in IO. Different probe configurations were used to generate varying artifacts, and both routine and low dose protocols were evaluated. Each set of reconstructed basis images were processed with sMARIO, and monoenergetic data ranging from 40 to 150 keV were generated for both the original and the sMARIO basis images using vendor-provided offline algorithms. Independent ROIs (27 mm3) were semi-automatically placed within the water and iodine rod for each dataset at matching locations, and the average value within each ROI was recorded to access the precision of the generated data to classify iodine vs water. For each distribution of water and iodine ROI values, the receiver operating curve (ROC) and the area under the ROC curve (AUC) were computed. Spectral MARIO was able to effectively correct a substantial contribution of metal artifacts from the image data across all keVs. Specifically, sMARIO recovered ~77% of the AUC loss due to metal artifact at low keV (40-70 keV) and 57% of the AUC loss at high keV (120- 150 keV). The recorded AUC of 0.98 at low keV with sMARIO demonstrates the ability to accurately classify small iodine concentrations even in the vicinity of metallic objects used in IO procedures.

Authors

Institutions

Publication Details

Published
2025-04-07
DOI
https://doi.org/10.1117/12.3048954
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AI-based spectral metal artifact reduction algorithm for improved iodine detection in virtual monoenergetic images: a quantitative assessment for interventional oncology applications

A. Missert, Wenchao Cao, Christopher Favazza, Andrea Ferrero
Advanced X-ray and CT Imaging
article

AI-based spectral metal artifact reduction algorithm for improved iodine detection in virtual monoenergetic images: a quantitative assessment for interventional oncology applications

A. Missert, Wenchao Cao, Christopher Favazza, Andrea Ferrero
article en

Abstract

In this work, we developed a deep CNN based spectral metal artifact reduction algorithm for interventional oncology applications (sMARIO) and quantitatively assessed its performance pertaining to iodine contrast detectability. CNN models were trained specifically for each basis images for spectral CT using patient data with the virtual insertion of metallic probes. Two solid rods (2.5 cm in diameter) representing water and 2mgI/ml iodinated solution, respectively, were inserted in a anthropomorphic phantom and scanned on a spectral CT scanner in both presence and absence of metallic probes used in IO. Different probe configurations were used to generate varying artifacts, and both routine and low dose protocols were evaluated. Each set of reconstructed basis images were processed with sMARIO, and monoenergetic data ranging from 40 to 150 keV were generated for both the original and the sMARIO basis images using vendor-provided offline algorithms. Independent ROIs (27 mm3) were semi-automatically placed within the water and iodine rod for each dataset at matching locations, and the average value within each ROI was recorded to access the precision of the generated data to classify iodine vs water. For each distribution of water and iodine ROI values, the receiver operating curve (ROC) and the area under the ROC curve (AUC) were computed. Spectral MARIO was able to effectively correct a substantial contribution of metal artifacts from the image data across all keVs. Specifically, sMARIO recovered ~77% of the AUC loss due to metal artifact at low keV (40-70 keV) and 57% of the AUC loss at high keV (120- 150 keV). The recorded AUC of 0.98 at low keV with sMARIO demonstrates the ability to accurately classify small iodine concentrations even in the vicinity of metallic objects used in IO procedures.

Thomas Jefferson University (US), WinnMed (US)
Openalex Percentile: Top 93%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.