Development of Electroconductive Polypyrrole‐Polycaprolactone and Poly(3,4‐Ethylenedioxythiophene)‐poly(Styrenesulfonate)‐Polyethylene Oxide Fibrous Scaffolds by Pressurised Gyration for Cardiac Tissue Engineering Applications

Abstract Cardiac patches, typically made from non‐conductive polymers, are a promising treatment for myocardial infarction (MI). Introducing electroconductive fibres in these patches improves clinical outcomes, but current production methods are limited. This study aims to design and manufacture electroconductive polymeric cardiac scaffolds that closely match native tissue, using pressurised gyration (PG) and conductive polymers (CP). In this study, for the first time, fibres from polypyrrole (PPy) with polycaprolactone (PCL) in chloroform and Poly(3,4‐ethylenedioxythiophene)‐poly(styrenesulfonate) (PEDOT:PSS) with polyethylene oxide (PEO) in water, are pressure spun with varying CP concentrations (5–10% w/v) and applied pressures (0–0.2 MPa). SEM shows fibres resemble the thickness and uniformity of natural cardiac fibres, as PEDOT:PSS 5%, 0 MPa matched endomysium, PEDOT:PSS 10%, 0 MPa aligned with perimysium, and PPy 7.5%, 0 MPa mimicked epimysium fibres, with diameters of 0.38, 1.02, and 3.88 µm, respectively. Four‐point probe testing reveals the closest electrical conductivity measurement to the reported cardiac chambers values is 0.22 S m −1 , achieved by PPy 10%, 0.2MPa. FTIR verified the absence of residual solvent, confirming conductivity is due to polymer bonds. The study confirms the produced fibres have ideal electroconductive and physicochemical properties for cardiac tissue engineering, demonstrating PG's potential as a scalable technique for electroconductive fibres manufacturing, advancing cardiac patch development and MI treatment.

Authors

Institutions

Publication Details

Journal
Macromolecular Materials and Engineering
Published
2025-04-07
DOI
https://doi.org/10.1002/mame.202500031
Citations
1
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Electroconductive Polypyrrole‐Polycaprolactone and Poly(3,4‐Ethylenedioxythiophene)‐poly(Styrenesulfonate)‐Polyethylene Oxide Fibrous Scaffolds by Pressurised Gyration for Cardiac Tissue Engineering Applications

Manul Amarakoon, Júlio César Cruz Fernandez, Rupy Kaur Matharu, Mohan Edirisinghe
1 citations
Macromolecular Materials and Engineering
Advanced Sensor and Energy Harvesting Materials
0.67
article

Development of Electroconductive Polypyrrole‐Polycaprolactone and Poly(3,4‐Ethylenedioxythiophene)‐poly(Styrenesulfonate)‐Polyethylene Oxide Fibrous Scaffolds by Pressurised Gyration for Cardiac Tissue Engineering Applications

Manul Amarakoon, Júlio César Cruz Fernandez, Rupy Kaur Matharu, Mohan Edirisinghe
article en
1 citations

Abstract

Abstract Cardiac patches, typically made from non‐conductive polymers, are a promising treatment for myocardial infarction (MI). Introducing electroconductive fibres in these patches improves clinical outcomes, but current production methods are limited. This study aims to design and manufacture electroconductive polymeric cardiac scaffolds that closely match native tissue, using pressurised gyration (PG) and conductive polymers (CP). In this study, for the first time, fibres from polypyrrole (PPy) with polycaprolactone (PCL) in chloroform and Poly(3,4‐ethylenedioxythiophene)‐poly(styrenesulfonate) (PEDOT:PSS) with polyethylene oxide (PEO) in water, are pressure spun with varying CP concentrations (5–10% w/v) and applied pressures (0–0.2 MPa). SEM shows fibres resemble the thickness and uniformity of natural cardiac fibres, as PEDOT:PSS 5%, 0 MPa matched endomysium, PEDOT:PSS 10%, 0 MPa aligned with perimysium, and PPy 7.5%, 0 MPa mimicked epimysium fibres, with diameters of 0.38, 1.02, and 3.88 µm, respectively. Four‐point probe testing reveals the closest electrical conductivity measurement to the reported cardiac chambers values is 0.22 S m −1 , achieved by PPy 10%, 0.2MPa. FTIR verified the absence of residual solvent, confirming conductivity is due to polymer bonds. The study confirms the produced fibres have ideal electroconductive and physicochemical properties for cardiac tissue engineering, demonstrating PG's potential as a scalable technique for electroconductive fibres manufacturing, advancing cardiac patch development and MI treatment.

Macromolecular Materials and EngineeringVol. 310(8)
University College London (GB)
Openalex Percentile: Top 33%
Advanced Sensor and Energy Harvesting Materials
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.