Analisis dan Perencanaan Pencahayaan Buatan pada Toko Kelontong Menggunakan DIAlux Evo 12.0

A grocery store must consider the comfort of people engaging in activities within it, one of which is lighting. Good lighting is an essential part of visual comfort. According to SNI 6197:2020, the standard illumination level for grocery stores is 300 lux. However, initial measurements revealed that during nighttime, the illumination level in the grocery store did not meet the standard, with an average measured illumination level of only 35 lux. Based on this issue, this study aims to determine the appropriate lighting design for grocery stores through analysis using the DIAlux EVO 12.0 software. This research employs the ADDIE research and development model, which comprises five stages: analysis, design, development, implementation, and evaluation. The results of the study, following development using the DIAlux EVO 12.0 software, indicate that five lighting points are required in the grocery store using Philips LED Bulb 19-watt Cool Daylight lamps. After implementation, re-measurements showed that the average nighttime illumination level reached 308 lux. Therefore, the research and development on lighting levels in the grocery store can be considered successful, as it significantly improved lighting in areas or conditions with illumination levels below the Indonesian National Standard.

Authors

Institutions

Publication Details

Journal
Jurnal Penelitian Rumpun Ilmu Teknik
Published
2025-03-17
DOI
https://doi.org/10.55606/juprit.v4i2.4931
Primary Topic
Computer Science and Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analisis dan Perencanaan Pencahayaan Buatan pada Toko Kelontong Menggunakan DIAlux Evo 12.0

Tatyantoro Andrasto, Riana Defi Mahadji Putri, Muhammad Harlanu, Ahmad Yusif
Jurnal Penelitian Rumpun Ilmu Teknik
Computer Science and Engineering
article

Analisis dan Perencanaan Pencahayaan Buatan pada Toko Kelontong Menggunakan DIAlux Evo 12.0

Tatyantoro Andrasto, Riana Defi Mahadji Putri, Muhammad Harlanu, Ahmad Yusif
article en

Abstract

A grocery store must consider the comfort of people engaging in activities within it, one of which is lighting. Good lighting is an essential part of visual comfort. According to SNI 6197:2020, the standard illumination level for grocery stores is 300 lux. However, initial measurements revealed that during nighttime, the illumination level in the grocery store did not meet the standard, with an average measured illumination level of only 35 lux. Based on this issue, this study aims to determine the appropriate lighting design for grocery stores through analysis using the DIAlux EVO 12.0 software. This research employs the ADDIE research and development model, which comprises five stages: analysis, design, development, implementation, and evaluation. The results of the study, following development using the DIAlux EVO 12.0 software, indicate that five lighting points are required in the grocery store using Philips LED Bulb 19-watt Cool Daylight lamps. After implementation, re-measurements showed that the average nighttime illumination level reached 308 lux. Therefore, the research and development on lighting levels in the grocery store can be considered successful, as it significantly improved lighting in areas or conditions with illumination levels below the Indonesian National Standard.

Jurnal Penelitian Rumpun Ilmu TeknikVol. 4(2)
State University of Semarang (ID)
Openalex Percentile: Top 97%
Computer Science and Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.