On grid-independency of CFD-DEM simulations of cluster-induced turbulence

We present a comparative study on the influence of three different particle (data) mapping methods on various one-point and two-point cluster-induced turbulence (CIT) statistics in an unbounded fluidization system. These methods include the particle centroid method (PCM), the divided particle volume method (DPVM), and a newly proposed implementation of Gaussian kernel method referred to as GaussFace method. In PCM method, the entire particle data is allocated to the cell, in which the particle centroid is located. However, in DPVM, the particle data is subdivided into smaller volumes using a satellite point method, allowing the distribution of particle properties among the cells associated with the satellite points. We performed simulations of dilute and dense systems at grid sizes between 2.22 d p − 8 . 88 d p and two smoothing characteristic sizes. Our results reveal that solely using GaussFace method, which is based on distributing particle data to surrounding cells employing a Gaussian kernel, leads to a smoother particle field compared to the PCM and DPVM. Furthermore, we find that grid-independent results can only be obtained by GaussFace method together with subsequent smoothing. We also observe that the grid-independence criterion identified for the dilute system is also valid for the dense system. In addition, comparing two different methods of separating the spatially correlated and uncorrelated particle velocity components reveals that the commonly adopted fixed filter approach grossly underestimates the granular temperature in the dilute regions. The findings of our study can serve as a reference for obtaining high-resolution CFD-DEM results, which, in turn, can be used to develop coarse-grid models. • Effect of particle data mapping methods on CIT statistics was demonstrated. • Fixed vs. adaptive filter methods compared for evaluating granular temperature. • Smoothing of particle fields is key to achieving grid-independent results. • The same grid-independence criterion for dilute systems can apply to dense systems.

Authors

Institutions

Publication Details

Journal
International Journal of Multiphase Flow
Published
2025-04-07
DOI
https://doi.org/10.1016/j.ijmultiphaseflow.2025.105223
Citations
6
Primary Topic
Particle Dynamics in Fluid Flows
Type
article
Field-Weighted Citation Impact
6.87
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On grid-independency of CFD-DEM simulations of cluster-induced turbulence

Behrad Esgandari, Simon Schneiderbauer
6 citations
International Journal of Multiphase Flow
Particle Dynamics in Fluid Flows
6.87
article

On grid-independency of CFD-DEM simulations of cluster-induced turbulence

Behrad Esgandari, Simon Schneiderbauer
article en
6 citations

Abstract

We present a comparative study on the influence of three different particle (data) mapping methods on various one-point and two-point cluster-induced turbulence (CIT) statistics in an unbounded fluidization system. These methods include the particle centroid method (PCM), the divided particle volume method (DPVM), and a newly proposed implementation of Gaussian kernel method referred to as GaussFace method. In PCM method, the entire particle data is allocated to the cell, in which the particle centroid is located. However, in DPVM, the particle data is subdivided into smaller volumes using a satellite point method, allowing the distribution of particle properties among the cells associated with the satellite points. We performed simulations of dilute and dense systems at grid sizes between 2.22 d p − 8 . 88 d p and two smoothing characteristic sizes. Our results reveal that solely using GaussFace method, which is based on distributing particle data to surrounding cells employing a Gaussian kernel, leads to a smoother particle field compared to the PCM and DPVM. Furthermore, we find that grid-independent results can only be obtained by GaussFace method together with subsequent smoothing. We also observe that the grid-independence criterion identified for the dilute system is also valid for the dense system. In addition, comparing two different methods of separating the spatially correlated and uncorrelated particle velocity components reveals that the commonly adopted fixed filter approach grossly underestimates the granular temperature in the dilute regions. The findings of our study can serve as a reference for obtaining high-resolution CFD-DEM results, which, in turn, can be used to develop coarse-grid models. • Effect of particle data mapping methods on CIT statistics was demonstrated. • Fixed vs. adaptive filter methods compared for evaluating granular temperature. • Smoothing of particle fields is key to achieving grid-independent results. • The same grid-independence criterion for dilute systems can apply to dense systems.

International Journal of Multiphase FlowVol. 188
Johannes Kepler University of Linz (AT)
Climate action
Openalex Percentile: Top 3%
Particle Dynamics in Fluid Flows
6.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.