Development of the timing system for the X-ray imaging and spectroscopy mission

We describe the development, design, ground verification, and in-orbit verification, performance measurement, and calibration of the timing system for the X-Ray Imaging and Spectroscopy Mission (XRISM). The scientific goals of the mission require an absolute timing accuracy of 1.0 ms. All components of the timing system were designed and verified to be within the timing error budgets, which were assigned by component to meet the requirements. After the launch of XRISM, the timing capability of the ground-tuned timing system was verified using the millisecond pulsar PSR B1937+21 during the commissioning period, and the timing jitter of the bus and the ground component were found to be below 15 μs compared with the NICER (Neutron star Interior Composition ExploreR) profile. During the performance verification and calibration period, simultaneous observations of the Crab pulsar by XRISM, NuSTAR (Nuclear Spectroscopic Telescope Array), and NICER were made to measure the absolute timing offset of the system, showing that the arrival time of the main pulse with XRISM was aligned with that of NICER and NuSTAR to within 200 μs. In conclusion, the absolute timing accuracy of the bus and the ground component of the XRISM timing system meets the timing error budget of 500 μs.

Authors

Institutions

Publication Details

Journal
Journal of Astronomical Telescopes Instruments and Systems
Published
2025-04-07
DOI
https://doi.org/10.1117/1.jatis.11.4.042007
Citations
1
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
1.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of the timing system for the X-ray imaging and spectroscopy mission

T. Takagi, Kotaro Fukushima, Ken Ebisawa, Katsuhiro Hayashi et al.
1 citations
Journal of Astronomical Telescopes Instruments and Systems
Atomic and Subatomic Physics Research
1.25
article

Development of the timing system for the X-ray imaging and spectroscopy mission

T. Takagi, Kotaro Fukushima, Ken Ebisawa, Katsuhiro Hayashi, M. Shidatsu, So Kato, Satoshi Eguchi, Chikara Natsukari, Hideki Uchiyama, Y. Terada, Ryo Iizuka, Chuen Siang Kang, K. Mukai, Akio Hoshino, Eric D. Miller, Yoshiaki Kanemaru, Ryohei Sato, Kenji Hamaguchi, Rie Sato, Anna Ogorzałek, Tsuyoshi Miyazaki, Hironori Maejima, Robert Hill, Minami Sakama, Takashi Kominato, Takaaki Tanaka, Satoru Katsuda, M. Tashiro, M. Yamauchi, Teruaki Enoto, Makoto Sawada, Naomi Ota, Mihoko Yukita, Kenichi Toda, François Mernier, T. Yoneyama, Kazuhiro Nakazawa, Isabella Brewer, H. Takahashi, Yuusuke Uchida, A. Tanimoto, Yugo Motogami, Morgan D. Waddy, Mark Mekosh, Yuki Niida, Satoshi Yamada, Nagomi Uchida, Yohko Tsuboi, Shin Watanabe, Shoji Ogawa, Matt Holland, Tessei Yoshida, Katja Pottschmidt, Masayoshi Nobukawa, Tsunefumi Mizuno, Aya Kubota, Shin’ichiro Uno, Yuichi Terashima, Michael Loewenstein, Tahir Yaqoob, Tomoko Nakamoto, Chris Baluta, Takumi Shioiri, Joseph B. Fox, Emily Aldoretta
article en
1 citations

Abstract

We describe the development, design, ground verification, and in-orbit verification, performance measurement, and calibration of the timing system for the X-Ray Imaging and Spectroscopy Mission (XRISM). The scientific goals of the mission require an absolute timing accuracy of 1.0 ms. All components of the timing system were designed and verified to be within the timing error budgets, which were assigned by component to meet the requirements. After the launch of XRISM, the timing capability of the ground-tuned timing system was verified using the millisecond pulsar PSR B1937+21 during the commissioning period, and the timing jitter of the bus and the ground component were found to be below 15 μs compared with the NICER (Neutron star Interior Composition ExploreR) profile. During the performance verification and calibration period, simultaneous observations of the Crab pulsar by XRISM, NuSTAR (Nuclear Spectroscopic Telescope Array), and NICER were made to measure the absolute timing offset of the system, showing that the arrival time of the main pulse with XRISM was aligned with that of NICER and NuSTAR to within 200 μs. In conclusion, the absolute timing accuracy of the bus and the ground component of the XRISM timing system meets the timing error budget of 500 μs.

Journal of Astronomical Telescopes Instruments and SystemsVol. 11(04)
Kagoshima University (JP), Hiroshima University (JP), NEC (Japan) (JP), Kumamoto Gakuen University (JP), Nihon Fukushi University (JP), Shizuoka University (JP), Goddard Space Flight Center (US), Rikkyo University (JP), Nara University of Education (JP), Konan University (JP), Tokyo University of Science (JP), Shibaura Institute of Technology (JP), Kyoto University (JP), Japan Aerospace Exploration Agency (JP), National Aeronautics and Space Administration (US), Institute of Space and Astronautical Science (JP), RIKEN Nishina Center (JP), Adnet Systems (United States) (US), Ehime University (JP), Nagoya University (JP), Massachusetts Institute of Technology (US), Saitama University (JP), Chuo University (JP), Nara Women's University (JP)
National Aeronautics and Space Administration, Nuclear Safety and Security Commission, Goddard Space Flight Center, Japan Society for the Promotion of Science
Openalex Percentile: Top 22%
Atomic and Subatomic Physics Research
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.