Comparative study of finned tube geometries and TPMS heat exchangers for enhanced freshwater production in humid environments

• Annular finned tubes double condensation rates compared to smooth surfaces. • Gyroid-Solid TPMS yields 40 % higher condensation than annular finned tubes. • IWP-Solid TPMS has 10 % higher freshwater output than annular finned tubes. • Gyroid sheet excels at high flow rates, boosting turbulence for more condensation. • TPMS structures show potential in optimizing freshwater production efficiency. This study investigates freshwater production from atmospheric air using various tube shapes and orientations, including smooth and finned surfaces, as well as structures based on triply periodic minimum surface (TPMS) topologies: Schoen's Gyroid and IWP. Utilizing verified 3D computational fluid dynamics (CFD) models, the research compares the efficiency of these designs under identical humidity and flow conditions, focusing on optimizing surface area for enhanced water vapor condensation. The findings reveal that horizontally oriented tubes outperform vertical ones, primarily due to their larger length-to-diameter ratio and the fins alignment. Notably, a horizontal annular finned tube significantly boosted the condensation rate by a factor of 2.3. The Gyroid-Solid TPMS structure demonstrated a 40 % increase in water production compared to the annular finned tube, while the IWP-Solid structure produced 10 % more. Conversely, at low Reynolds numbers, Gyroid and IWP sheet structures condensed less water than finned tube due to the lower flow momentum through the TPMS pores. However, at higher Reynolds numbers, the Gyroid sheet outperformed the finned tube by enhancing flow turbulence, with the IWP- Sheet structure yielding comparable results. This study underscores the potential of TPMS structures and the impact of flow dynamics and orientation on optimizing freshwater production from atmospheric air.

Authors

Institutions

Publication Details

Journal
International Journal of Thermofluids
Published
2025-04-07
DOI
https://doi.org/10.1016/j.ijft.2025.101190
Citations
6
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
4.28

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative study of finned tube geometries and TPMS heat exchangers for enhanced freshwater production in humid environments

Kabbir Ali, Rashid K. Abu Al‐Rub, Mohamed I. Hassan Ali, Omar Abdelqader
6 citations
International Journal of Thermofluids
Heat Transfer and Optimization
4.28
article

Comparative study of finned tube geometries and TPMS heat exchangers for enhanced freshwater production in humid environments

Kabbir Ali, Rashid K. Abu Al‐Rub, Mohamed I. Hassan Ali, Omar Abdelqader
article en
6 citations

Abstract

• Annular finned tubes double condensation rates compared to smooth surfaces. • Gyroid-Solid TPMS yields 40 % higher condensation than annular finned tubes. • IWP-Solid TPMS has 10 % higher freshwater output than annular finned tubes. • Gyroid sheet excels at high flow rates, boosting turbulence for more condensation. • TPMS structures show potential in optimizing freshwater production efficiency. This study investigates freshwater production from atmospheric air using various tube shapes and orientations, including smooth and finned surfaces, as well as structures based on triply periodic minimum surface (TPMS) topologies: Schoen's Gyroid and IWP. Utilizing verified 3D computational fluid dynamics (CFD) models, the research compares the efficiency of these designs under identical humidity and flow conditions, focusing on optimizing surface area for enhanced water vapor condensation. The findings reveal that horizontally oriented tubes outperform vertical ones, primarily due to their larger length-to-diameter ratio and the fins alignment. Notably, a horizontal annular finned tube significantly boosted the condensation rate by a factor of 2.3. The Gyroid-Solid TPMS structure demonstrated a 40 % increase in water production compared to the annular finned tube, while the IWP-Solid structure produced 10 % more. Conversely, at low Reynolds numbers, Gyroid and IWP sheet structures condensed less water than finned tube due to the lower flow momentum through the TPMS pores. However, at higher Reynolds numbers, the Gyroid sheet outperformed the finned tube by enhancing flow turbulence, with the IWP- Sheet structure yielding comparable results. This study underscores the potential of TPMS structures and the impact of flow dynamics and orientation on optimizing freshwater production from atmospheric air.

International Journal of ThermofluidsVol. 27
Khalifa University of Science and Technology (AE)
Khalifa University of Science, Technology and Research, Malawi University of Science and Technology, Center for Membranes and Advanced Water Technology, Khalifa University
Openalex Percentile: Top 6%
Heat Transfer and Optimization
4.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.