INVESTIGATION OF THE COMPLEX OF VIBRATION AND EXTERNAL MAGNETIC FIELD PARAMETERS IN THE TASKS OF DIAGNOSTICS OF SYNCHRONOUS GENERATORS OF GAS PISTON UNITS

Vibration diagnostics of rotating electric machines is quite well studied and has become widespread, since vibration indicators directly depend on the electrical and mechanical condition of the machine. However, as a number of studies have shown, the analysis of vibration parameters alone does not always allow for an accurate diagnosis. This is especially true for gas piston units, in which the vibration of the internal combustion engine has a significant effect on the synchronous alternator. The aim of the study was to increase the reliability of the results of vibration diagnostics of piston units in operation with synchronous generators with excitation from stationary magnets. A complex of diagnostics of gas piston aggregates based on vibration parameters and the external magnetic field of the generator is proposed. The study was carried out at a working gas-piston power plant consisting of six units with a single capacity of 2 MW operating parallel to the grid. With the help of a portable vibration analyzer "Korsar+", measurements of the RMS value of vibration at the control points of internal combustion engines and synchronous generators, analysis of the obtained spectra and a preliminary diagnosis of the condition were carried out. To clarify the diagnosis, measurements of the external magnetic field of synchronous generators were carried out using the P3-80 electric and magnetic field strength meter, analysis of the amplitude values of the magnetic field strength and spectral characteristics obtained by fast Fourier transform. The results obtained showed the dependence of the spectral composition of the external magnetic field strength on the presence of defects in the windings of the alternating current generator and made it possible to increase the reliability of diagnosis by unambiguously determining the source of increased vibration.

Authors

Publication Details

Journal
Bulletin of the South Ural State University series Power Engineering
Published
2025-01-01
DOI
https://doi.org/10.14529/power250105
Primary Topic
Advanced Power Generation Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

INVESTIGATION OF THE COMPLEX OF VIBRATION AND EXTERNAL MAGNETIC FIELD PARAMETERS IN THE TASKS OF DIAGNOSTICS OF SYNCHRONOUS GENERATORS OF GAS PISTON UNITS

Azat V. Zayniev
Bulletin of the South Ural State University series Power Engineering
Advanced Power Generation Technologies
article

INVESTIGATION OF THE COMPLEX OF VIBRATION AND EXTERNAL MAGNETIC FIELD PARAMETERS IN THE TASKS OF DIAGNOSTICS OF SYNCHRONOUS GENERATORS OF GAS PISTON UNITS

Azat V. Zayniev
article en

Abstract

Vibration diagnostics of rotating electric machines is quite well studied and has become widespread, since vibration indicators directly depend on the electrical and mechanical condition of the machine. However, as a number of studies have shown, the analysis of vibration parameters alone does not always allow for an accurate diagnosis. This is especially true for gas piston units, in which the vibration of the internal combustion engine has a significant effect on the synchronous alternator. The aim of the study was to increase the reliability of the results of vibration diagnostics of piston units in operation with synchronous generators with excitation from stationary magnets. A complex of diagnostics of gas piston aggregates based on vibration parameters and the external magnetic field of the generator is proposed. The study was carried out at a working gas-piston power plant consisting of six units with a single capacity of 2 MW operating parallel to the grid. With the help of a portable vibration analyzer "Korsar+", measurements of the RMS value of vibration at the control points of internal combustion engines and synchronous generators, analysis of the obtained spectra and a preliminary diagnosis of the condition were carried out. To clarify the diagnosis, measurements of the external magnetic field of synchronous generators were carried out using the P3-80 electric and magnetic field strength meter, analysis of the amplitude values of the magnetic field strength and spectral characteristics obtained by fast Fourier transform. The results obtained showed the dependence of the spectral composition of the external magnetic field strength on the presence of defects in the windings of the alternating current generator and made it possible to increase the reliability of diagnosis by unambiguously determining the source of increased vibration.

Bulletin of the South Ural State University series Power EngineeringVol. 25(1)
Affordable and clean energy
Openalex Percentile: Top 95%
Advanced Power Generation Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.