The In Vivo Biological Response to Intra‐Articular Injected Polycarbonate Urethane Wear Debris Particles

Wear particles invariably form due to contact and friction between articulating surfaces in orthopedic prosthetic joint replacements. Polycarbonate urethane (PCU) has shown low wear rates and invoked minimal local biological response to wear debris in various orthopedic applications. However, controlled preclinical studies have not yet studied the biological response to PCU particles in synovial joints. This study aims to evaluate the biological response to mostly submicron-sized PCU wear particles in synovial joints in a rabbit model representing a worst-case scenario. PCU and ultra-high-molecular-weight-polyethene (UHMWPE) particles were generated in vitro, and particle characterization was performed using scanning electron microscopy (SEM) images. Fifteen New Zealand white rabbits, divided into three groups, received bilateral injections in the knee joint with 10 mg/mL PCU, UHMWPE particles, or saline (all 0.2 mL). After 3 months, the biological response in the joint was evaluated by histopathological reactivity scoring. The generated PCU and UHMWPE wear particles were mainly in the biologically active size range with an average equivalent circle diameter (ECD) of 0.31 μm (±0.48) and 6.99 μm (±16.32), respectively. There was a minimal to non-existing biological response (score ≤ 0.5) to PCU (0.5 ± 1.0), UHMWPE particles (0.6 ± 1.3) and saline (0.0 ± 0.0). Also, the wear particles did not disperse from the injection site. The results of this study support the use of PCU as a bearing surface in orthopedic prosthetic joint replacements by indicating that even in the likelihood that wear particles are generated, they are not likely to trigger a strong inflammatory response.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Materials Research Part B Applied Biomaterials
Published
2025-04-01
DOI
https://doi.org/10.1002/jbm.b.35579
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The In Vivo Biological Response to Intra‐Articular Injected Polycarbonate Urethane Wear Debris Particles

Alex K. Roth, Ilona M. Punt, Martijn Poeze, Ryan Siskey et al.
Journal of Biomedical Materials Research Part B Applied Biomaterials
Orthopaedic implants and arthroplasty
article

The In Vivo Biological Response to Intra‐Articular Injected Polycarbonate Urethane Wear Debris Particles

Alex K. Roth, Ilona M. Punt, Martijn Poeze, Ryan Siskey, Jane A. E. Gruisen, Pieter J. Emans, Aylvin A. Dias
article en

Abstract

Wear particles invariably form due to contact and friction between articulating surfaces in orthopedic prosthetic joint replacements. Polycarbonate urethane (PCU) has shown low wear rates and invoked minimal local biological response to wear debris in various orthopedic applications. However, controlled preclinical studies have not yet studied the biological response to PCU particles in synovial joints. This study aims to evaluate the biological response to mostly submicron-sized PCU wear particles in synovial joints in a rabbit model representing a worst-case scenario. PCU and ultra-high-molecular-weight-polyethene (UHMWPE) particles were generated in vitro, and particle characterization was performed using scanning electron microscopy (SEM) images. Fifteen New Zealand white rabbits, divided into three groups, received bilateral injections in the knee joint with 10 mg/mL PCU, UHMWPE particles, or saline (all 0.2 mL). After 3 months, the biological response in the joint was evaluated by histopathological reactivity scoring. The generated PCU and UHMWPE wear particles were mainly in the biologically active size range with an average equivalent circle diameter (ECD) of 0.31 μm (±0.48) and 6.99 μm (±16.32), respectively. There was a minimal to non-existing biological response (score ≤ 0.5) to PCU (0.5 ± 1.0), UHMWPE particles (0.6 ± 1.3) and saline (0.0 ± 0.0). Also, the wear particles did not disperse from the injection site. The results of this study support the use of PCU as a bearing surface in orthopedic prosthetic joint replacements by indicating that even in the likelihood that wear particles are generated, they are not likely to trigger a strong inflammatory response.

Journal of Biomedical Materials Research Part B Applied BiomaterialsVol. 113(4)
DSM (Netherlands) (NL), Exponent (United States) (US), Maastricht University Medical Centre (NL)
Openalex Percentile: Top 88%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.