Dynamometer Resistance Pad Position Influences Knee Strength and Hamstring/Quadriceps Ratio in Professional Basketball Players: Retrospective Observational Study

Some knee strength measuring devices have an anterior cushioning area but relies on a belt for the posterior pad adjustment, creating an uneven force distribution. This study analyzed whether the distal pad position affects knee strength measurements. Eleven professional basketball players participated in this study, with a total of 22 knees evaluated. Knee flexion and extension dynamometric measurements were performed at different angular velocities: 30°/s, 120°/s, and 240°/s. For each angular velocity, two measurements were performed with varying positions of the measuring tool pad at the anterior and posterior aspects (AA and PA). The hamstring/quadriceps (H/Q) ratio was calculated by dividing the hamstring musculature’s maximum peak strength by the quadricep musculature’s maximum peak strength at each measurement. The knee work was extracted from the device after finishing the measurements. Significant differences were found between measurement positions in the knee flexion force at 30°/s (p < 0.001) and 120°/s (p = 0.027). No differences were found for the extension forces. As for the H/Q ratio, significant differences were found between positions at 30°/s (p < 0.001). Furthermore, significant differences between positions were found for the knee work at 120°/s (p = 0.019). These findings suggest that the positioning of the pad on the leg directly influences knee flexor strength measurements, which in turn impacts critical parameters, such as the H/Q ratio and knee work. Given the importance of these variables in injury prevention, particularly for conditions such as anterior cruciate ligament (ACL) injuries, ensuring precise and reliable measurement methods is essential. We recommend using the PA position because it increases knee flexion strength values, potentially leading to more accurate assessments of the muscle function and balance.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-04-04
DOI
https://doi.org/10.3390/app15074000
Primary Topic
Sports Performance and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamometer Resistance Pad Position Influences Knee Strength and Hamstring/Quadriceps Ratio in Professional Basketball Players: Retrospective Observational Study

Néstor Pérez Mallada, María Jesús Martínez Beltrán, Lucía Cuéllar Marín, Juan Manuel Arribas Marín et al.
Applied Sciences
Sports Performance and Training
article

Dynamometer Resistance Pad Position Influences Knee Strength and Hamstring/Quadriceps Ratio in Professional Basketball Players: Retrospective Observational Study

Néstor Pérez Mallada, María Jesús Martínez Beltrán, Lucía Cuéllar Marín, Juan Manuel Arribas Marín, Pablo José Borrás Luján, O Arroyo, R.L. Martin
article en

Abstract

Some knee strength measuring devices have an anterior cushioning area but relies on a belt for the posterior pad adjustment, creating an uneven force distribution. This study analyzed whether the distal pad position affects knee strength measurements. Eleven professional basketball players participated in this study, with a total of 22 knees evaluated. Knee flexion and extension dynamometric measurements were performed at different angular velocities: 30°/s, 120°/s, and 240°/s. For each angular velocity, two measurements were performed with varying positions of the measuring tool pad at the anterior and posterior aspects (AA and PA). The hamstring/quadriceps (H/Q) ratio was calculated by dividing the hamstring musculature’s maximum peak strength by the quadricep musculature’s maximum peak strength at each measurement. The knee work was extracted from the device after finishing the measurements. Significant differences were found between measurement positions in the knee flexion force at 30°/s (p < 0.001) and 120°/s (p = 0.027). No differences were found for the extension forces. As for the H/Q ratio, significant differences were found between positions at 30°/s (p < 0.001). Furthermore, significant differences between positions were found for the knee work at 120°/s (p = 0.019). These findings suggest that the positioning of the pad on the leg directly influences knee flexor strength measurements, which in turn impacts critical parameters, such as the H/Q ratio and knee work. Given the importance of these variables in injury prevention, particularly for conditions such as anterior cruciate ligament (ACL) injuries, ensuring precise and reliable measurement methods is essential. We recommend using the PA position because it increases knee flexion strength values, potentially leading to more accurate assessments of the muscle function and balance.

Applied SciencesVol. 15(7)
Universidad Pontificia Comillas (ES)
Openalex Percentile: Top 91%
Sports Performance and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.