Revolutionizing silver quantification: a novel ternary surfactant system with 2-nitro-6-(thiazol-2-yl-diazenyl)phenol and Triton X-100 for enhanced spectrophotometric analysis

Although modern reported methods, such as AAS, ICP-AES, ICP-MS, have good sensitivity, the high cost of equipment, the need for sophisticated instruments, separation and preconcentration steps and experienced technicians along with lack of precise methods make them cumbersome. Solid phase extraction (SPE) emerges as an attractive technique that reduces solvent consumption, minimizes exposure, shortens extraction time, and lowers disposal costs. Herein, a pioneering methodology for the quantification of minute amounts of silver is introduced, using 2-nitro-6-(thiazol-2-yl-diazenyl)phenol (NTDP) as a complexing agent and Triton X-100 as a nonionic surfactant within a ternary surfactant system at a pH of 5.3. This novel extraction strategy demonstrated selective preconcentration. The enriched solution was subjected to spectrophotometric analysis for the quantification of the analyte. After refining extraction and complexation parameters, a remarkable 250-fold increase in the enrichment factor was attained, highlighting a sensitivity boost of 509 times compared with traditional extraction approaches relying solely on nonionic surfactants. The key parameters of molar absorptivity and Sandell sensitivity were determined to be 6.04 × 10<sup>6</sup> L mol<sup>-1</sup> cm<sup>-1</sup> and 0.0018 ng cm<sup>-2</sup>, respectively. The calibration plot was observed from 5.0-175 ng mL<sup>-1</sup>, whereas Ringbom optimum concentrations ranged from 15-160 ng mL<sup>-1</sup>. The detection and quantification limits were 1.63 and 4.95 ng mL<sup>-1</sup>, respectively. The relative standard deviation (RSD) of the complex was 2.27. The suggested method was efficiently utilized for assessing the Ag<sup>+</sup> concentration in real samples, producing acceptable outcomes.

Authors

Institutions

Publication Details

Journal
RSC Advances
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ra00352k
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Revolutionizing silver quantification: a novel ternary surfactant system with 2-nitro-6-(thiazol-2-yl-diazenyl)phenol and Triton X-100 for enhanced spectrophotometric analysis

Khaled F. Debbabi, Alaa S. Amin, Salah M. El‐Bahy, Refat El‐Sayed et al.
RSC Advances
Electrochemical Analysis and Applications
article

Revolutionizing silver quantification: a novel ternary surfactant system with 2-nitro-6-(thiazol-2-yl-diazenyl)phenol and Triton X-100 for enhanced spectrophotometric analysis

Khaled F. Debbabi, Alaa S. Amin, Salah M. El‐Bahy, Refat El‐Sayed, Muneera Alrasheedi
article en

Abstract

Although modern reported methods, such as AAS, ICP-AES, ICP-MS, have good sensitivity, the high cost of equipment, the need for sophisticated instruments, separation and preconcentration steps and experienced technicians along with lack of precise methods make them cumbersome. Solid phase extraction (SPE) emerges as an attractive technique that reduces solvent consumption, minimizes exposure, shortens extraction time, and lowers disposal costs. Herein, a pioneering methodology for the quantification of minute amounts of silver is introduced, using 2-nitro-6-(thiazol-2-yl-diazenyl)phenol (NTDP) as a complexing agent and Triton X-100 as a nonionic surfactant within a ternary surfactant system at a pH of 5.3. This novel extraction strategy demonstrated selective preconcentration. The enriched solution was subjected to spectrophotometric analysis for the quantification of the analyte. After refining extraction and complexation parameters, a remarkable 250-fold increase in the enrichment factor was attained, highlighting a sensitivity boost of 509 times compared with traditional extraction approaches relying solely on nonionic surfactants. The key parameters of molar absorptivity and Sandell sensitivity were determined to be 6.04 × 10<sup>6</sup> L mol<sup>-1</sup> cm<sup>-1</sup> and 0.0018 ng cm<sup>-2</sup>, respectively. The calibration plot was observed from 5.0-175 ng mL<sup>-1</sup>, whereas Ringbom optimum concentrations ranged from 15-160 ng mL<sup>-1</sup>. The detection and quantification limits were 1.63 and 4.95 ng mL<sup>-1</sup>, respectively. The relative standard deviation (RSD) of the complex was 2.27. The suggested method was efficiently utilized for assessing the Ag<sup>+</sup> concentration in real samples, producing acceptable outcomes.

RSC AdvancesVol. 15(14)
Qassim University (SA), University of Monastir (TN), Taif University (SA), Umm al-Qura University (SA), Benha University (EG)
Taif University
Clean water and sanitation
Openalex Percentile: Top 93%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.