Characteristics of partial discharge development in high voltage cables at different temperature

In order to elucidate the influence of temperature on the characteristics of cable partial discharge, this paper designs and produces a discharge model along the surface and tip under laboratory conditions. Additionally, a temperature control box and partial discharge measurement system are constructed to investigate the impact of temperature on the generation of cable partial discharge. The experimental results indicate that, when the temperature increases from 20°C to 90°C under the large load operation condition, the partial discharge onset voltage of the defective model decreases, although the trend is different. Additionally, the amplitude of the partial discharge pulse and the maximum discharge volume increase with the increase of temperature. The conclusions of this study provide a fundamental basis for detecting the development characteristics of partial discharges and evaluating the insulation degradation condition under different temperatures.

Authors

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icpadm61663.2024.10945941
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characteristics of partial discharge development in high voltage cables at different temperature

Zeli Ju, Siwen Wang, Sichen Qin, Xiahaoyue Yun et al.
High voltage insulation and dielectric phenomena
article

Characteristics of partial discharge development in high voltage cables at different temperature

Zeli Ju, Siwen Wang, Sichen Qin, Xiahaoyue Yun, Qian Wang, Haofei Sun, Kun Zhou, Lu Pu
article en

Abstract

In order to elucidate the influence of temperature on the characteristics of cable partial discharge, this paper designs and produces a discharge model along the surface and tip under laboratory conditions. Additionally, a temperature control box and partial discharge measurement system are constructed to investigate the impact of temperature on the generation of cable partial discharge. The experimental results indicate that, when the temperature increases from 20°C to 90°C under the large load operation condition, the partial discharge onset voltage of the defective model decreases, although the trend is different. Additionally, the amplitude of the partial discharge pulse and the maximum discharge volume increase with the increase of temperature. The conclusions of this study provide a fundamental basis for detecting the development characteristics of partial discharges and evaluating the insulation degradation condition under different temperatures.

Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 82%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Characteristics of partial discharge development in high voltage cables at different temperature — Zeli Ju, Siwen Wang, et al. · (2024) | TGRS Research Map | TGRS