Lower limb deformity correction using Ortho-SUV frame in skeletally mature patients

Background Gradual correction of lower limb deformity using the Ilizarov apparatus is an established method. The Ortho-SUV frame is a computer-assisted system that simultaneously allows accurate and timely correction of various deformities. Patients and methods This prospective study included 13 patients with various lower limb deformities (femur and tibia) treated with an Ortho-SUV frame in one center between October 2020 and December 2023. Results The correction time ranged from 3 to 49 days. Correction accuracy was full in 12 (92.31%) patients and residual 10 degrees of plantar flexion in one (7.69%) patient. The number of schedules for correction was one in four (30.77%) patients, two in eight (61.54%) patients, and three in one (7.69%) patients. The union time ranged from 79 to 285 days, with a mean of 154.3 (±60.9). The time in frame ranged from 81 to 362 with a mean of 204 (±86.37). The follow-up duration ranged from 5.8 to 38.17 months, with a mean of 24.59 (±11.05). Conclusion Lower limb deformity correction using the Ortho-SUV resulted in the accurate correction of simultaneous deformities.

Authors

Institutions

Publication Details

Journal
The Egyptian Orthopaedic Journal
Published
2024-10-01
DOI
https://doi.org/10.4103/eoj.eoj_91_24
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lower limb deformity correction using Ortho-SUV frame in skeletally mature patients

Ahmed Elsheikh, Mohsen A. Mashhour, Waleed Soliman Mohammed
The Egyptian Orthopaedic Journal
Bone fractures and treatments
article

Lower limb deformity correction using Ortho-SUV frame in skeletally mature patients

Ahmed Elsheikh, Mohsen A. Mashhour, Waleed Soliman Mohammed
article en

Abstract

Background Gradual correction of lower limb deformity using the Ilizarov apparatus is an established method. The Ortho-SUV frame is a computer-assisted system that simultaneously allows accurate and timely correction of various deformities. Patients and methods This prospective study included 13 patients with various lower limb deformities (femur and tibia) treated with an Ortho-SUV frame in one center between October 2020 and December 2023. Results The correction time ranged from 3 to 49 days. Correction accuracy was full in 12 (92.31%) patients and residual 10 degrees of plantar flexion in one (7.69%) patient. The number of schedules for correction was one in four (30.77%) patients, two in eight (61.54%) patients, and three in one (7.69%) patients. The union time ranged from 79 to 285 days, with a mean of 154.3 (±60.9). The time in frame ranged from 81 to 362 with a mean of 204 (±86.37). The follow-up duration ranged from 5.8 to 38.17 months, with a mean of 24.59 (±11.05). Conclusion Lower limb deformity correction using the Ortho-SUV resulted in the accurate correction of simultaneous deformities.

The Egyptian Orthopaedic JournalVol. 59(4)
Benha University (EG)
Openalex Percentile: Top 61%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Lower limb deformity correction using Ortho-SUV frame in skeletally mature patients — Ahmed Elsheikh, Mohsen A. Mashhour, et al. · The Egyptian Orthopaedic Journal (2024) | TGRS Research Map | TGRS