Effect of collimator thickness on the imaging performance of coded-aperture gamma camera

The coded-aperture gamma camera has significant applications in the fields of space exploration, nuclear security, nuclear industry, and nuclear medicine. The coded-aperture collimator is a key component for modulating gamma rays, and its parameters are important factors to optimize the performance of gamma cameras. In this paper, the impact of collimator thickness on the fully coded field of view and angular resolution was determined through Monte Carlo simulation and experimental verification. By introducing the equivalent thickness, the conventional calculation formulas were modified to improve the calculation accuracy. In addition, the variation in the reconstructed image quality with the collimator thickness was quantitatively evaluated by the contrast-to-noise ratio and normalized mean squared error, thereby establishing the relationship between the gamma-ray transmittance and the imaging quality. The results indicate that for medium- and high-energy gamma rays, the optimal imaging quality is achieved when the gamma-ray transmittance corresponding to collimator thicknesses ranges from 12% to 16%. These research findings provide reference standards for the design of coded-aperture collimators to meet the requirements of different applications.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-04-01
DOI
https://doi.org/10.1063/5.0239695
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of collimator thickness on the imaging performance of coded-aperture gamma camera

Gangqiang Zha, Donghai Fan, Tingting Tan
Review of Scientific Instruments
Medical Imaging Techniques and Applications
article

Effect of collimator thickness on the imaging performance of coded-aperture gamma camera

Gangqiang Zha, Donghai Fan, Tingting Tan
article en

Abstract

The coded-aperture gamma camera has significant applications in the fields of space exploration, nuclear security, nuclear industry, and nuclear medicine. The coded-aperture collimator is a key component for modulating gamma rays, and its parameters are important factors to optimize the performance of gamma cameras. In this paper, the impact of collimator thickness on the fully coded field of view and angular resolution was determined through Monte Carlo simulation and experimental verification. By introducing the equivalent thickness, the conventional calculation formulas were modified to improve the calculation accuracy. In addition, the variation in the reconstructed image quality with the collimator thickness was quantitatively evaluated by the contrast-to-noise ratio and normalized mean squared error, thereby establishing the relationship between the gamma-ray transmittance and the imaging quality. The results indicate that for medium- and high-energy gamma rays, the optimal imaging quality is achieved when the gamma-ray transmittance corresponding to collimator thicknesses ranges from 12% to 16%. These research findings provide reference standards for the design of coded-aperture collimators to meet the requirements of different applications.

Review of Scientific InstrumentsVol. 96(4)
Northwestern Polytechnical University (CN), Research & Development Institute (US), State Key Laboratory of Solidification Processing
National Natural Science Foundation of China, National Key Research and Development Program of China
Industry, innovation and infrastructure
Openalex Percentile: Top 89%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.