Development of a robotic calibration system for the motional Stark effect diagnostic on the EAST tokamak

The Motional Stark Effect (MSE) diagnostic is one of the key methods for measuring the current density distribution in magnetically confined fusion plasmas. On the Experimental Advanced Superconducting Tokamak, a calibration system based on a collaborative robot has been developed to enhance the accuracy of the calibration work during the maintenance period. This robotic calibration system uses a camera to automatically capture the observation sightlines and generates polarized light with an accuracy of ∼0.5 mdeg. Additionally, it records the MSE diagnostic response at each angle of polarized light perpendicular to the sightlines. This process supports the rapid sightline geometric calibration and facilitates the collection of polarization responses across various spatial positions and angles, even within the complex environment of the tokamak vacuum vessel. The new robotic calibration system significantly improves measurement precision, reduces calibration time, and provides high-quality calibration data. The maximum fitting deviation of the polarization angle has been reduced to less than 0.2°.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-04-01
DOI
https://doi.org/10.1063/5.0255375
Citations
1
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
1.87

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a robotic calibration system for the motional Stark effect diagnostic on the EAST tokamak

Jia Fu, J.P. Qian, Zichao Lin, Bo Lyu et al.
1 citations
Review of Scientific Instruments
Magnetic confinement fusion research
1.87
article

Development of a robotic calibration system for the motional Stark effect diagnostic on the EAST tokamak

Jia Fu, J.P. Qian, Zichao Lin, Bo Lyu, Yifei Jin, Yang Yang, Hongming Zhang, Fudi Wang, Rui Ding, Dian Lu, Shengyu Fu, H.W. Deng, Yichao Li, Huajian Ji
article en
1 citations

Abstract

The Motional Stark Effect (MSE) diagnostic is one of the key methods for measuring the current density distribution in magnetically confined fusion plasmas. On the Experimental Advanced Superconducting Tokamak, a calibration system based on a collaborative robot has been developed to enhance the accuracy of the calibration work during the maintenance period. This robotic calibration system uses a camera to automatically capture the observation sightlines and generates polarized light with an accuracy of ∼0.5 mdeg. Additionally, it records the MSE diagnostic response at each angle of polarized light perpendicular to the sightlines. This process supports the rapid sightline geometric calibration and facilitates the collection of polarization responses across various spatial positions and angles, even within the complex environment of the tokamak vacuum vessel. The new robotic calibration system significantly improves measurement precision, reduces calibration time, and provides high-quality calibration data. The maximum fitting deviation of the polarization angle has been reduced to less than 0.2°.

Review of Scientific InstrumentsVol. 96(4)
University of Science and Technology of China (CN), Chinese Academy of Sciences (CN)
National Magnetic Confinement Fusion Program of China
Openalex Percentile: Top 15%
Magnetic confinement fusion research
1.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.