Experimental Measurement and Energy Evaluation of the Geothermal Water Energy Utilization in a Thermal Swimming Pool

This work focuses on the experimental measurement of the temperature and flow of cold, geothermal, pool and waste pool water of a thermal swimming pool in southern Slovakia. The measured quantities are necessary for the energy evaluation of geothermal water energy utilization. It is clear from experience that the geothermal energy utilization rate often does not even reach 40%. The remaining energy is considered waste, and in the form of waste pool water with too high temperature, it is most often discharged into surface streams. The results of the study showed that by applying appropriate measures to recover heat from waste pool water, it is possible to increase the energy utilization rate of thermal water from 40% to 85%, which is the ideal energy utilization rate according to energy point of view. At the end of the article, methods will be presented, thanks to which it would be possible to reduce the temperature of waste pool water to the value required by law and at the same time increase the rate of thermal water energy use.

Authors

Institutions

Publication Details

Journal
Periodica Polytechnica Mechanical Engineering
Published
2025-04-07
DOI
https://doi.org/10.3311/ppme.38200
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Measurement and Energy Evaluation of the Geothermal Water Energy Utilization in a Thermal Swimming Pool

Ján Takács, Georg Rockel, Ján Iľko, Anna Predajnianska
Periodica Polytechnica Mechanical Engineering
Heat Transfer and Optimization
article

Experimental Measurement and Energy Evaluation of the Geothermal Water Energy Utilization in a Thermal Swimming Pool

Ján Takács, Georg Rockel, Ján Iľko, Anna Predajnianska
article en

Abstract

This work focuses on the experimental measurement of the temperature and flow of cold, geothermal, pool and waste pool water of a thermal swimming pool in southern Slovakia. The measured quantities are necessary for the energy evaluation of geothermal water energy utilization. It is clear from experience that the geothermal energy utilization rate often does not even reach 40%. The remaining energy is considered waste, and in the form of waste pool water with too high temperature, it is most often discharged into surface streams. The results of the study showed that by applying appropriate measures to recover heat from waste pool water, it is possible to increase the energy utilization rate of thermal water from 40% to 85%, which is the ideal energy utilization rate according to energy point of view. At the end of the article, methods will be presented, thanks to which it would be possible to reduce the temperature of waste pool water to the value required by law and at the same time increase the rate of thermal water energy use.

Periodica Polytechnica Mechanical EngineeringVol. 69(2)
Slovak University of Technology in Bratislava (SK), Emerson (Germany) (DE), Mendel University in Brno (CZ)
Openalex Percentile: Top 94%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.