Measuring Variable Discharge Under Partially Full Pipe Flow

Accurately measuring the discharge in partially full pipe flow is both difficult and demanding. In this regard, a new meter sensor using microwave technology has been evaluated for determining partially full pipe discharge across a range of flow depths. A range of experiments with smooth PVC pipes of two different pipe diameters (101.6 and 152.4 mm) at two different pipe slopes (1° and 2°) were carried out under turbulent (Reynolds numbers = (0.27–3.25) × 105) and supercritical flows with Froude numbers Fr in the range of 1.5 ≤ Fr ≤ 3.6. Our results showed that when combining the microwave sensor readings with either the Chezy equation or Manning’s law, reliable discharge predictions were found compared to the measured discharge across all experiments. The range of R2 values obtained from the plots of predicted versus measured discharge were all greater than 97%, indicating an accuracy allowing the meter to be used in commercial applications.

Authors

Institutions

Publication Details

Journal
Processes
Published
2025-04-04
DOI
https://doi.org/10.3390/pr13041089
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measuring Variable Discharge Under Partially Full Pipe Flow

Vasiliki Koutsospyrou, Ashraf El‐Hamalawi, Martin Croft, Graham Sander et al.
Processes
Flow Measurement and Analysis
article

Measuring Variable Discharge Under Partially Full Pipe Flow

Vasiliki Koutsospyrou, Ashraf El‐Hamalawi, Martin Croft, Graham Sander, D. M. A. WALLACE
article en

Abstract

Accurately measuring the discharge in partially full pipe flow is both difficult and demanding. In this regard, a new meter sensor using microwave technology has been evaluated for determining partially full pipe discharge across a range of flow depths. A range of experiments with smooth PVC pipes of two different pipe diameters (101.6 and 152.4 mm) at two different pipe slopes (1° and 2°) were carried out under turbulent (Reynolds numbers = (0.27–3.25) × 105) and supercritical flows with Froude numbers Fr in the range of 1.5 ≤ Fr ≤ 3.6. Our results showed that when combining the microwave sensor readings with either the Chezy equation or Manning’s law, reliable discharge predictions were found compared to the measured discharge across all experiments. The range of R2 values obtained from the plots of predicted versus measured discharge were all greater than 97%, indicating an accuracy allowing the meter to be used in commercial applications.

ProcessesVol. 13(4)
Loughborough University (GB)
Engineering and Physical Sciences Research Council
Openalex Percentile: Top 92%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.