DEVELOPMENT OF A PRECOLUMN DERIVATIZATION METHOD FOR THE QUANTITATIVE DETECTION OF ETHYLENEDIAMINE IMPURITY IN PHARMACEUTICAL DRUGS USING RP-HPLC COUPLED WITH UV/PDA DETECTOR

The proposed study aimed to create and validate a technique for detecting impurities in drug substances, specifically targeting low levels of ethylenediamine in pharmaceutical raw materials. The method involved the use of benzoyl chloride as a derivatizing agent, during pre-column derivatization processing, effectively boosting the sensitivity and precision of the method. Chromatographic conditions were optimized, including the use of 0.7g L-1 di-sodium hydrogen phosphate anhydrous and methanol, a specific XBridgeTM Shield RP-18 column, 10μL injection volume, and a flow rate of 0.8mL min-1 at 25°C. This method combined precolumn derivatization with RP-HPLC UV/PDA detection, proving highly sensitive and precise with favorable linearity (r ≥ 0.99) and precision (% RSD/CV < 5.0) upon validation. The developed method is noted for its simplicity, speed, cost-effectiveness, and suitability for regular analysis in QC labs, particularly for detecting impurities in drug candidates.

Authors

Publication Details

Journal
INDIAN DRUGS
Published
2025-03-28
DOI
https://doi.org/10.53879/id.62.03.14788
Citations
1
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DEVELOPMENT OF A PRECOLUMN DERIVATIZATION METHOD FOR THE QUANTITATIVE DETECTION OF ETHYLENEDIAMINE IMPURITY IN PHARMACEUTICAL DRUGS USING RP-HPLC COUPLED WITH UV/PDA DETECTOR

Pankaj Garg, Abhishek Sharma, Mukesh Kumar
1 citations
INDIAN DRUGS
Analytical Methods in Pharmaceuticals
0.75
article

DEVELOPMENT OF A PRECOLUMN DERIVATIZATION METHOD FOR THE QUANTITATIVE DETECTION OF ETHYLENEDIAMINE IMPURITY IN PHARMACEUTICAL DRUGS USING RP-HPLC COUPLED WITH UV/PDA DETECTOR

Pankaj Garg, Abhishek Sharma, Mukesh Kumar
article en
1 citations

Abstract

The proposed study aimed to create and validate a technique for detecting impurities in drug substances, specifically targeting low levels of ethylenediamine in pharmaceutical raw materials. The method involved the use of benzoyl chloride as a derivatizing agent, during pre-column derivatization processing, effectively boosting the sensitivity and precision of the method. Chromatographic conditions were optimized, including the use of 0.7g L-1 di-sodium hydrogen phosphate anhydrous and methanol, a specific XBridgeTM Shield RP-18 column, 10μL injection volume, and a flow rate of 0.8mL min-1 at 25°C. This method combined precolumn derivatization with RP-HPLC UV/PDA detection, proving highly sensitive and precise with favorable linearity (r ≥ 0.99) and precision (% RSD/CV < 5.0) upon validation. The developed method is noted for its simplicity, speed, cost-effectiveness, and suitability for regular analysis in QC labs, particularly for detecting impurities in drug candidates.

INDIAN DRUGSVol. 62(03)
Openalex Percentile: Top 34%
Analytical Methods in Pharmaceuticals
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.