Correlation analysis of BMD in different regions of the vertebrae determined by QCT and DXA on pedicle screw loosening

Low bone mineral density (BMD) impairs the stability of the bone-screw interface, which leads to screw loosening after spinal instrumentation. Quantitative computed tomography (QCT) and dual-energy X-ray absorptiometry (DXA) were applied to measure BMD of screw trajectories and other regions of the vertebrae in this paper, and the aim was to analyze the best effective tool and BMD of the best appropriate vertebral site to predict pedicle screw loosening after lumbar fusion surgery. 186 patients who underwent lumbar interbody fusion and pedicle screws placement were analyzed retrospectively. Patients were divided into 2 groups according to whether there was screw loosening: fissure is greater than or equal to 1 mm around the screws at follow-up CT scans. The volumetric BMD (vBMD) was measured by QCT in the central vertebral body, pedicle, and screw trajectory region, and DXA was applied for the lumbar spine and hip area BMD (aBMD). The overall pedicle screw loosening rate was 33.9% (63/186). Demographic data, health history, and the lumbar aBMD were not significantly different between the two groups. Multivariate analysis revealed showed that the hip aBMD, vBMD in the central vertebral body, pedicle, and screw trajectory regions were independent risk factors for screw loosening. Additionally, Receiver operating characteristic curve revealed the screw trajectory vBMD had the greatest area under the curve for predicting screw loosening. The screw trajectory vBMD using QCT had a stronger predictive value than the vBMD in other regions of the vertebrae and the hip aBMD, and had a more representative bone quality measurement in the bone-screw binding region.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-04-07
DOI
https://doi.org/10.1038/s41598-025-91816-0
Citations
1
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correlation analysis of BMD in different regions of the vertebrae determined by QCT and DXA on pedicle screw loosening

Dong Liang, Xiaoqiang Huang, Jiachen Ji, Yuting Zhang et al.
1 citations
Scientific Reports
Medical Imaging and Analysis
0.67
article

Correlation analysis of BMD in different regions of the vertebrae determined by QCT and DXA on pedicle screw loosening

Dong Liang, Xiaoqiang Huang, Jiachen Ji, Yuting Zhang, Xu Chen
article en
1 citations

Abstract

Low bone mineral density (BMD) impairs the stability of the bone-screw interface, which leads to screw loosening after spinal instrumentation. Quantitative computed tomography (QCT) and dual-energy X-ray absorptiometry (DXA) were applied to measure BMD of screw trajectories and other regions of the vertebrae in this paper, and the aim was to analyze the best effective tool and BMD of the best appropriate vertebral site to predict pedicle screw loosening after lumbar fusion surgery. 186 patients who underwent lumbar interbody fusion and pedicle screws placement were analyzed retrospectively. Patients were divided into 2 groups according to whether there was screw loosening: fissure is greater than or equal to 1 mm around the screws at follow-up CT scans. The volumetric BMD (vBMD) was measured by QCT in the central vertebral body, pedicle, and screw trajectory region, and DXA was applied for the lumbar spine and hip area BMD (aBMD). The overall pedicle screw loosening rate was 33.9% (63/186). Demographic data, health history, and the lumbar aBMD were not significantly different between the two groups. Multivariate analysis revealed showed that the hip aBMD, vBMD in the central vertebral body, pedicle, and screw trajectory regions were independent risk factors for screw loosening. Additionally, Receiver operating characteristic curve revealed the screw trajectory vBMD had the greatest area under the curve for predicting screw loosening. The screw trajectory vBMD using QCT had a stronger predictive value than the vBMD in other regions of the vertebrae and the hip aBMD, and had a more representative bone quality measurement in the bone-screw binding region.

Scientific ReportsVol. 15(1)
Xi'an Medical University (CN)
Honghui Hospital, Natural Science Foundation of Shaanxi Province
Openalex Percentile: Top 33%
Medical Imaging and Analysis
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.