Encased Pultruded I-GFRP Beam under Impact Loading

This study experimentally investigated the behavioral impact of composite reinforced concrete (RC) beams that are strengthened with pultruded I-shaped glass fiber-reinforced polymer (GFRP) sections. Six specimens, divided into two categories, were fabricated in different arrangements. Three specimens were subjected to both impact loading and subsequent static loading in the first category to evaluate their residual static strength after impact. The second category, also consisting of three specimens, was tested under static loading only to provide baseline data for comparison. Key variables included the presence of the GFRP I-section, shear connectors, and varying drop heights during impact tests. A 42.5 kg mass was dropped at the mid-span of the beams from heights of 250, 500, 1,000, 1,500, and 1,900 mm. The composite specimens with GFRP I-sections showed significantly higher maximum impact forces, with increases of 19% and 77% for beams without and with shear connectors, respectively, compared to the reference beam under the same drop height conditions. The composite specimens exhibited drops in the maximum deflections at the mid-span compared to the control specimen. These reductions were 9.4% and 21%, respectively, when the drop height was 1,900 mm.

Authors

Institutions

Publication Details

Published
2025-04-07
DOI
https://doi.org/10.1061/9780784486085.005
Primary Topic
Structural Response to Dynamic Loads
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Encased Pultruded I-GFRP Beam under Impact Loading

Abbas A. Allawi, Teghreed H. Ibrahim, Ayman El‐Zohairy
Structural Response to Dynamic Loads
article

Encased Pultruded I-GFRP Beam under Impact Loading

Abbas A. Allawi, Teghreed H. Ibrahim, Ayman El‐Zohairy
article en

Abstract

This study experimentally investigated the behavioral impact of composite reinforced concrete (RC) beams that are strengthened with pultruded I-shaped glass fiber-reinforced polymer (GFRP) sections. Six specimens, divided into two categories, were fabricated in different arrangements. Three specimens were subjected to both impact loading and subsequent static loading in the first category to evaluate their residual static strength after impact. The second category, also consisting of three specimens, was tested under static loading only to provide baseline data for comparison. Key variables included the presence of the GFRP I-section, shear connectors, and varying drop heights during impact tests. A 42.5 kg mass was dropped at the mid-span of the beams from heights of 250, 500, 1,000, 1,500, and 1,900 mm. The composite specimens with GFRP I-sections showed significantly higher maximum impact forces, with increases of 19% and 77% for beams without and with shear connectors, respectively, compared to the reference beam under the same drop height conditions. The composite specimens exhibited drops in the maximum deflections at the mid-span compared to the control specimen. These reductions were 9.4% and 21%, respectively, when the drop height was 1,900 mm.

University of Baghdad (IQ)
Openalex Percentile: Top 93%
Structural Response to Dynamic Loads
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.