Enhancing Seismic Resilience of Pre-Code RC Building: A Fragility Assessment

A braced frame significantly enhances structural efficiency and provides essential lateral stiffness. Incorporating retrofitting elements transforms the structure into a proficient system capable of achieving higher elevations. Self-centering energy dissipating braces (SCEDs) are among the most effective seismic resistance frameworks due to their ability to dissipate energy under lateral seismic loads and enhance retrofit designs. This study examines the seismic vulnerability of a pre-code reinforced concrete moment-resisting frame equipped with SCEDs through seismic fragility curves. The structural analysis includes brace implementation and soft story condition assessment at the ground level. Non-linear analyses are conducted to evaluate the seismic performance of an eight-storey and six-storey structure with single diagonal braces. Incremental dynamic analysis is then performed using a set of accelerograms compatible with UAE site conditions. Maximum story drift is used as the demand parameter, and drift ratios for various seismic performance levels—immediate occupancy, life safety, and collapse prevention—are selected based on HAZUS guidelines. The IDA curves are then used to generate seismic fragility curves through structural reliability relations.

Authors

Institutions

Publication Details

Published
2025-04-07
DOI
https://doi.org/10.1061/9780784486085.041
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Seismic Resilience of Pre-Code RC Building: A Fragility Assessment

Aman M. Mwafy, Steffi Stephen, Anas Issa
Seismic Performance and Analysis
article

Enhancing Seismic Resilience of Pre-Code RC Building: A Fragility Assessment

Aman M. Mwafy, Steffi Stephen, Anas Issa
article en

Abstract

A braced frame significantly enhances structural efficiency and provides essential lateral stiffness. Incorporating retrofitting elements transforms the structure into a proficient system capable of achieving higher elevations. Self-centering energy dissipating braces (SCEDs) are among the most effective seismic resistance frameworks due to their ability to dissipate energy under lateral seismic loads and enhance retrofit designs. This study examines the seismic vulnerability of a pre-code reinforced concrete moment-resisting frame equipped with SCEDs through seismic fragility curves. The structural analysis includes brace implementation and soft story condition assessment at the ground level. Non-linear analyses are conducted to evaluate the seismic performance of an eight-storey and six-storey structure with single diagonal braces. Incremental dynamic analysis is then performed using a set of accelerograms compatible with UAE site conditions. Maximum story drift is used as the demand parameter, and drift ratios for various seismic performance levels—immediate occupancy, life safety, and collapse prevention—are selected based on HAZUS guidelines. The IDA curves are then used to generate seismic fragility curves through structural reliability relations.

United Arab Emirates University (AE)
Climate action
Openalex Percentile: Top 93%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhancing Seismic Resilience of Pre-Code RC Building: A Fragility Assessment — Aman M. Mwafy, Steffi Stephen, et al. · (2025) | TGRS Research Map | TGRS