Analysis of temperature detection performance of vibration-rotation Raman lidar based on different calibration functions

Rotational Raman (RR) lidar is widely employed for atmospheric temperature detection, but its detection capability is constrained in cloudy or hazy conditions due to the interference of elastic scattering leakage to the pure RR channels. To address this limitation, a vibrational-rotational Raman (VR) temperature measurement technique has been proposed and validated. This study compares the performance of VR and RR techniques through simulations and observational experiments. The simulations account for both the theoretical (intrinsic) errors of the methods and the impact of random errors. Additionally, this study evaluates the performance of ten calibration functions (CFs) in the VR method, including nine applied to VR for the first time. The results indicate that when the signal-to-noise ratio of the low quantum number channel is low, the VR technique can effectively improve the detection performance of the system. For the VR technique, all tested CFs can successfully retrieve atmospheric temperature. Among them, the four-coefficient forward CFs achieve the best calibration performance within the calibration interval, while the linear CF performs best in extrapolation scenarios.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-04-07
DOI
https://doi.org/10.1364/oe.559941
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of temperature detection performance of vibration-rotation Raman lidar based on different calibration functions

Haokai Yang, Rongzheng Cao, Wangshu Tan, Junshuai Liu et al.
Optics Express
Spectroscopy Techniques in Biomedical and Chemical Research
article

Analysis of temperature detection performance of vibration-rotation Raman lidar based on different calibration functions

Haokai Yang, Rongzheng Cao, Wangshu Tan, Junshuai Liu, He Chen, Rui Hu, Siying Chen, Y. H. Xie, Pan Guo, Jie Yu, Zhichao Bu, Yinghong Yu
article en

Abstract

Rotational Raman (RR) lidar is widely employed for atmospheric temperature detection, but its detection capability is constrained in cloudy or hazy conditions due to the interference of elastic scattering leakage to the pure RR channels. To address this limitation, a vibrational-rotational Raman (VR) temperature measurement technique has been proposed and validated. This study compares the performance of VR and RR techniques through simulations and observational experiments. The simulations account for both the theoretical (intrinsic) errors of the methods and the impact of random errors. Additionally, this study evaluates the performance of ten calibration functions (CFs) in the VR method, including nine applied to VR for the first time. The results indicate that when the signal-to-noise ratio of the low quantum number channel is low, the VR technique can effectively improve the detection performance of the system. For the VR technique, all tested CFs can successfully retrieve atmospheric temperature. Among them, the four-coefficient forward CFs achieve the best calibration performance within the calibration interval, while the linear CF performs best in extrapolation scenarios.

Optics ExpressVol. 33(9)
China Meteorological Administration (CN)
Affordable and clean energy
Openalex Percentile: Top 94%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.