Establishment of AC-DC transfer standard at SASO-NMCC

This paper documents the achievements of traceability and the technical evaluation of the newly established AC-DC Difference calibration service for AC voltage measurements at the NMCC, KSA. It gives details on the establishment and functioning of a new automatic calibrating system. This paper also includes instructions for the expanding uncertainty associated with the calibration system. Nevertheless, this study provides extensive review of heat converters and AC-DC difference measurements. The GULFMET.EM-S3 Supplementary Comparison data show the new system’s capabilities, which cover the 2mV to 1000V @ 10Hz to 1MHz range. It also describes the new capabilities of AC-DC difference calibration services and the accomplishment of traceability for AC voltage measurements by the NMCC in Saudi Arabia. It explains the installation and functioning of auto-calibrating system. This paper also guides the construction of calibration systems and the related extended uncertainty. Although it is not very detailed, this document gives an idea of what heat converters and AC-DC difference measurements are all about—the results of the GULFMET.EM-S3 Supplementary Comparisons are used to show what the new system is capable of. These capabilities range from 10 Hz to 1 MHz and 2 mV to 1000 V.

Authors

Institutions

Publication Details

Journal
EPJ Web of Conferences
Published
2025-01-01
DOI
https://doi.org/10.1051/epjconf/202532312006
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishment of AC-DC transfer standard at SASO-NMCC

Abdullah M Alrobaish, Ahmed N AlJomaie
EPJ Web of Conferences
Scientific Measurement and Uncertainty Evaluation
article

Establishment of AC-DC transfer standard at SASO-NMCC

Abdullah M Alrobaish, Ahmed N AlJomaie
article en

Abstract

This paper documents the achievements of traceability and the technical evaluation of the newly established AC-DC Difference calibration service for AC voltage measurements at the NMCC, KSA. It gives details on the establishment and functioning of a new automatic calibrating system. This paper also includes instructions for the expanding uncertainty associated with the calibration system. Nevertheless, this study provides extensive review of heat converters and AC-DC difference measurements. The GULFMET.EM-S3 Supplementary Comparison data show the new system’s capabilities, which cover the 2mV to 1000V @ 10Hz to 1MHz range. It also describes the new capabilities of AC-DC difference calibration services and the accomplishment of traceability for AC voltage measurements by the NMCC in Saudi Arabia. It explains the installation and functioning of auto-calibrating system. This paper also guides the construction of calibration systems and the related extended uncertainty. Although it is not very detailed, this document gives an idea of what heat converters and AC-DC difference measurements are all about—the results of the GULFMET.EM-S3 Supplementary Comparisons are used to show what the new system is capable of. These capabilities range from 10 Hz to 1 MHz and 2 mV to 1000 V.

EPJ Web of ConferencesVol. 323
National Institute of Measurement and Testing Technology (CN)
Openalex Percentile: Top 93%
Scientific Measurement and Uncertainty Evaluation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.