A dual channel non-contact pipeline strain measuring device

Strain information contains important dynamic characteristics of structure and could reflect the health status change inside the structure. In a narrow space, pipeline strain measurement could be a challenge in engineering. This paper employs a sensing beam to perform non-contact strain measurement. In this study, the frequency response function is used to assess the relation between the measured strain on the sensing beam and the true strain of pipeline structure. Then, we proposed a dual-channel measurement device that can be applied in narrow space to measure pipeline strain. The device is tested in an experiment platform, and the test results show that the sample variance of the continuous output signal is less than 0.7. The relative average deviation of the strain measurement results of the two channels of the measurement system is less than 9%.

Authors

Publication Details

Journal
Advances in Engineering Technology Research
Published
2025-04-01
DOI
https://doi.org/10.56028/aetr.13.1.543.2025
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A dual channel non-contact pipeline strain measuring device

Zhengbo Luo, Cheng Zhou, Zehan Li, Xiaoye Liu et al.
4 links
Advances in Engineering Technology Research
Advanced Sensor Technologies Research
article

A dual channel non-contact pipeline strain measuring device

Zhengbo Luo, Cheng Zhou, Zehan Li, Xiaoye Liu, Qingbo He, Jingkai Huang
article en

Abstract

Strain information contains important dynamic characteristics of structure and could reflect the health status change inside the structure. In a narrow space, pipeline strain measurement could be a challenge in engineering. This paper employs a sensing beam to perform non-contact strain measurement. In this study, the frequency response function is used to assess the relation between the measured strain on the sensing beam and the true strain of pipeline structure. Then, we proposed a dual-channel measurement device that can be applied in narrow space to measure pipeline strain. The device is tested in an experiment platform, and the test results show that the sample variance of the continuous output signal is less than 0.7. The relative average deviation of the strain measurement results of the two channels of the measurement system is less than 9%.

Advances in Engineering Technology ResearchVol. 13(1)
Openalex Percentile: Top 94%
Advanced Sensor Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A dual channel non-contact pipeline strain measuring device — Zhengbo Luo, Cheng Zhou, et al. · Advances in Engineering Technology Research (2025) | TGRS Research Map | TGRS