Longitudinal tracking of chronic inflammation through Calprotectin and Interleukin-6 using a sweat wearable device

This work demonstrates a continuous, noninvasive two-plex electrochemical biosensor for the measurement of inflammation in sweat via disease-specific and general markers Calprotectin and Interleukin-6 (IL-6), respectively. Sensor functionalization and sensor stability was characterized through Fourier Transform Infrared (FTIR) spectroscopy. Sensor stability was characterized through open circuit potential and electrochemical impedance spectroscopy (EIS). On-body stability was demonstrated through relative humidity and temperature measurements of the sensor-skin interface. Calprotectin and IL-6 were measured in sweat over 2 days from 2 chronically inflamed subjects and 10 healthy subjects to characterize dual sweat expression of the markers and investigate diurnal patterns of expression across the two groups. Sweat Calprotectin was continuously tracked over a 40-h period for chronically inflamed and healthy subjects with different inflammatory activity and treatments. Sensor measurements were recorded continuously with a sampling rate of 1–1.5 min. Significantly higher sweat Calprotectin and higher median sweat Calprotectin expression was observed in the morning-afternoon than in the evening among inflamed and healthy subjects, respectively. Higher median sweat IL-6 was observed in inflamed individuals in the morning-afternoon, while higher median sweat IL-6 was observed in healthy individuals in the evening. Temporal results of sweat Calprotectin tracking demonstrate higher basal Calprotectin in an unmedicated over a medicated inflamed subject, and higher basal Calprotectin of inflamed subjects over a healthy subject. Calprotectin and IL-6 demonstrated a strong positive linear relationship in sweat. Diurnal patterns were observed in the sweat of inflamed and healthy individuals, and continuous tracking of disease-specific inflammation through sweat Calprotectin was demonstrated. • A noninvasive, continuous electrochemical biosensor was developed for dynamic inflammation tracking in human sweat. • Demonstration of noninvasive, continuous tracking of Calprotectin and IL-6 in sweat. • Expression of Calprotectin and IL-6 measured in sweat for chronically inflamed and healthy individuals. • Investigation of diurnal patterns of sweat Calprotectin and IL-6 in chronically inflamed and healthy individuals. • This work demonstrates a sweat sensor for dual inflammatory markers for dynamic tracking of chronic inflammation.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics X
Published
2025-04-06
DOI
https://doi.org/10.1016/j.biosx.2025.100622
Citations
2
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
3.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Longitudinal tracking of chronic inflammation through Calprotectin and Interleukin-6 using a sweat wearable device

Sarah Shahub, Kai‐Chun Lin, Sriram Muthukumar, Shalini Prasad et al.
2 citations
Biosensors and Bioelectronics X
Respiratory Support and Mechanisms
3.04
article

Longitudinal tracking of chronic inflammation through Calprotectin and Interleukin-6 using a sweat wearable device

Sarah Shahub, Kai‐Chun Lin, Sriram Muthukumar, Shalini Prasad, Annapoorna Ramasubramanya, Ruchita Mahesh Kumar, Preeti Singh
article en
2 citations

Abstract

This work demonstrates a continuous, noninvasive two-plex electrochemical biosensor for the measurement of inflammation in sweat via disease-specific and general markers Calprotectin and Interleukin-6 (IL-6), respectively. Sensor functionalization and sensor stability was characterized through Fourier Transform Infrared (FTIR) spectroscopy. Sensor stability was characterized through open circuit potential and electrochemical impedance spectroscopy (EIS). On-body stability was demonstrated through relative humidity and temperature measurements of the sensor-skin interface. Calprotectin and IL-6 were measured in sweat over 2 days from 2 chronically inflamed subjects and 10 healthy subjects to characterize dual sweat expression of the markers and investigate diurnal patterns of expression across the two groups. Sweat Calprotectin was continuously tracked over a 40-h period for chronically inflamed and healthy subjects with different inflammatory activity and treatments. Sensor measurements were recorded continuously with a sampling rate of 1–1.5 min. Significantly higher sweat Calprotectin and higher median sweat Calprotectin expression was observed in the morning-afternoon than in the evening among inflamed and healthy subjects, respectively. Higher median sweat IL-6 was observed in inflamed individuals in the morning-afternoon, while higher median sweat IL-6 was observed in healthy individuals in the evening. Temporal results of sweat Calprotectin tracking demonstrate higher basal Calprotectin in an unmedicated over a medicated inflamed subject, and higher basal Calprotectin of inflamed subjects over a healthy subject. Calprotectin and IL-6 demonstrated a strong positive linear relationship in sweat. Diurnal patterns were observed in the sweat of inflamed and healthy individuals, and continuous tracking of disease-specific inflammation through sweat Calprotectin was demonstrated. • A noninvasive, continuous electrochemical biosensor was developed for dynamic inflammation tracking in human sweat. • Demonstration of noninvasive, continuous tracking of Calprotectin and IL-6 in sweat. • Expression of Calprotectin and IL-6 measured in sweat for chronically inflamed and healthy individuals. • Investigation of diurnal patterns of sweat Calprotectin and IL-6 in chronically inflamed and healthy individuals. • This work demonstrates a sweat sensor for dual inflammatory markers for dynamic tracking of chronic inflammation.

Biosensors and Bioelectronics XVol. 24
The University of Texas at Dallas (US)
Openalex Percentile: Top 10%
Respiratory Support and Mechanisms
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.