Development of a High‐Throughput Microscope for the Analysis of Peripheral Blood Smears for Anemia Screening

The conventional method of screening for anemia requires pathologists to manually examine slides via microscope, a tedious process during health emergencies. This study presents an automated high-throughput optical digital microscope system capable of sequentially scanning and analyzing 10 blood smear slides per batch in under 15 min using a Laplacian-based autofocusing algorithm at 40x magnification. The acquired images are segmented via the YOLOv5 algorithm, and morphological features of red blood cells (RBCs) are classified using a multilayer perceptron (MLP) model. The system achieved 90.6% accuracy, 95% precision, 91% sensitivity, and 94% specificity in classifying anemia subtypes (macrocytic, microcytic, normocytic) and healthy samples. The trained model is integrated into an Android application for real-time geographic mapping of anemic clusters, enabling healthcare workers to prioritize interventions efficiently. This high-throughput approach eliminates the need for immersion oil and manual slide handling, demonstrating significant potential for rapid, scalable anemia screening in resource-limited settings.

Authors

Institutions

Publication Details

Journal
Journal of Biophotonics
Published
2025-04-06
DOI
https://doi.org/10.1002/jbio.70024
Primary Topic
Image Processing Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a High‐Throughput Microscope for the Analysis of Peripheral Blood Smears for Anemia Screening

M. Sasikala, N. Ramadass, A M Arunnagiri, S. Mullai Venthan
Journal of Biophotonics
Image Processing Techniques and Applications
article

Development of a High‐Throughput Microscope for the Analysis of Peripheral Blood Smears for Anemia Screening

M. Sasikala, N. Ramadass, A M Arunnagiri, S. Mullai Venthan
article en

Abstract

The conventional method of screening for anemia requires pathologists to manually examine slides via microscope, a tedious process during health emergencies. This study presents an automated high-throughput optical digital microscope system capable of sequentially scanning and analyzing 10 blood smear slides per batch in under 15 min using a Laplacian-based autofocusing algorithm at 40x magnification. The acquired images are segmented via the YOLOv5 algorithm, and morphological features of red blood cells (RBCs) are classified using a multilayer perceptron (MLP) model. The system achieved 90.6% accuracy, 95% precision, 91% sensitivity, and 94% specificity in classifying anemia subtypes (macrocytic, microcytic, normocytic) and healthy samples. The trained model is integrated into an Android application for real-time geographic mapping of anemic clusters, enabling healthcare workers to prioritize interventions efficiently. This high-throughput approach eliminates the need for immersion oil and manual slide handling, demonstrating significant potential for rapid, scalable anemia screening in resource-limited settings.

Journal of BiophotonicsVol. 18(8)
Anna University, Chennai (IN)
Openalex Percentile: Top 90%
Image Processing Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.