An analysis of the application potential of protected zone ventilation in hospitals based on experiments and simulations

• The performance of the POV system across various function rooms of hospital has been investigated. • A comparison between the POV and TVAD systems was conducted to underscore the advantages of the POV system. • Key factors affecting the POV system efficiency have been identified. • POV system effectively segregates polluted and protected zones in hospitals. • Provided guidance and experience for the operation of different functional rooms of hospital. This study explored hospital indoor air environments using experiments and simulations, with a specific focus on assessing the performance of the protected occupied zone ventilation (POV) system across various function rooms. Optimize the parameters of the POV system by simulating the supply air velocity, temperature, and angle. Field measurements of POV system protection efficiency were conducted in the chamber. The results indicated that the efficiency of the POV system was influenced by supply air temperature, velocity, manikins’ thermal plume. Surprisingly, manikin position was not the primary factor affecting efficiency; instead, exhaust location significantly impacted air quality in the protected manikin's breathing zone and placing the exhaust in the polluted zone was found to enhance the effectiveness of the POV system in maintaining air quality. When the supply air velocity was 2 m/s, the protection efficiency exceeded 50 % in all cases. When all the exhausts were open and the patient manikin was close to the exhaust in the polluted zone, the protection efficiency exceeded 60 %. Moreover, even under high supply air velocity, the draught did not exceed the standard. Compared to total volume air distribution (TVAD) systems, the POV system effectively segregates polluted and protected zones, achieving isolation, while demonstrating a relatively low air exchange rate, highlighting its energy-saving potential. Finally, we observed that the indoor layout could impact the isolation effect. Therefore, we carefully noted variations in the setting of air supply parameters across different rooms to ensure the effective and customized application of POV systems in hospitals.

Authors

Institutions

Publication Details

Journal
Building and Environment
Published
2025-04-06
DOI
https://doi.org/10.1016/j.buildenv.2025.112975
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An analysis of the application potential of protected zone ventilation in hospitals based on experiments and simulations

Xingchi Jiang, Nuoa Lei, Amar Aganović, Cheng Zhu et al.
Building and Environment
Infection Control and Ventilation
article

An analysis of the application potential of protected zone ventilation in hospitals based on experiments and simulations

Xingchi Jiang, Nuoa Lei, Amar Aganović, Cheng Zhu, He Qin
article en

Abstract

• The performance of the POV system across various function rooms of hospital has been investigated. • A comparison between the POV and TVAD systems was conducted to underscore the advantages of the POV system. • Key factors affecting the POV system efficiency have been identified. • POV system effectively segregates polluted and protected zones in hospitals. • Provided guidance and experience for the operation of different functional rooms of hospital. This study explored hospital indoor air environments using experiments and simulations, with a specific focus on assessing the performance of the protected occupied zone ventilation (POV) system across various function rooms. Optimize the parameters of the POV system by simulating the supply air velocity, temperature, and angle. Field measurements of POV system protection efficiency were conducted in the chamber. The results indicated that the efficiency of the POV system was influenced by supply air temperature, velocity, manikins’ thermal plume. Surprisingly, manikin position was not the primary factor affecting efficiency; instead, exhaust location significantly impacted air quality in the protected manikin's breathing zone and placing the exhaust in the polluted zone was found to enhance the effectiveness of the POV system in maintaining air quality. When the supply air velocity was 2 m/s, the protection efficiency exceeded 50 % in all cases. When all the exhausts were open and the patient manikin was close to the exhaust in the polluted zone, the protection efficiency exceeded 60 %. Moreover, even under high supply air velocity, the draught did not exceed the standard. Compared to total volume air distribution (TVAD) systems, the POV system effectively segregates polluted and protected zones, achieving isolation, while demonstrating a relatively low air exchange rate, highlighting its energy-saving potential. Finally, we observed that the indoor layout could impact the isolation effect. Therefore, we carefully noted variations in the setting of air supply parameters across different rooms to ensure the effective and customized application of POV systems in hospitals.

Building and EnvironmentVol. 278
Lawrence Berkeley National Laboratory (US), Sichuan University (CN), UiT The Arctic University of Norway (NO)
National Natural Science Foundation of China
Openalex Percentile: Top 89%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.