Bending moments of PEEK-based root analog implants (RAIs)

Root-analog implants are frequently fabricated from titanium, which can be associated with various problems, e.g. hypersensitivity to titanium. In this study, we evaluate the bending moments of different polyetheretherketone-based root analog implants as a metal-free alternative. For this, an extracted tooth 31 and 36 was scanned to create an STL data set of each tooth. These were used to fabricate n = 8 polyetheretherketone-based root analog implants per group, with 5 groups being fabricated per tooth type. Two groups were additively manufactured using material extrusion. The other groups were milled from differnet polyetheretherketone grades. After artificial ageing, the samples were statically loaded until fracture in order to determine the bending moment. Of the root analog implants in the form of a 31, a white, milled polyetheretherketone grade showed the highest bending moment of 2835.3 ± 509.8 Nmm and an unfilled, additively processed polyetheretherketone grade the lowest. Of the RAIs in the form of a 36, an unfilled, milled polyetheretherketone grade showed the highest bending moment with 29342.6 ± 854.7 Nmm and a white, additively processed polyetheretherketone grade showed the lowest bending moment with 19880.5 ± 7188.6 Nmm. Basically, the results between the additively and subtractively processed groups were significantly different. In terms of mechanical requirements in the oral cavity, one-piece milled polyetheretherketone -based RAIs appear to provide more predictable results than additively manufactured ones. Taken together, our study suggests that more solidly designed one-piece root analog implants made of milled polyetheretherketone in the form of molars appear to be able to withstand the mechanical requirements of the oral cavity.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanics
Published
2025-04-06
DOI
https://doi.org/10.1016/j.jbiomech.2025.112677
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bending moments of PEEK-based root analog implants (RAIs)

Maren Soetebeer, Mats Wernfried Heinrich Böse, Hui Zhu, Andreas Dominik Schwitalla et al.
1 links
Journal of Biomechanics
Neuroscience and Neural Engineering
article

Bending moments of PEEK-based root analog implants (RAIs)

Maren Soetebeer, Mats Wernfried Heinrich Böse, Hui Zhu, Andreas Dominik Schwitalla, Robert Nicic, Dichen Li, Ufuk Adali, Jamila Yassine, Changning Sun, Franziska Schmidt, Guido Sterzenbach, Chuncheng Yang, Felizia Kesler
article en

Abstract

Root-analog implants are frequently fabricated from titanium, which can be associated with various problems, e.g. hypersensitivity to titanium. In this study, we evaluate the bending moments of different polyetheretherketone-based root analog implants as a metal-free alternative. For this, an extracted tooth 31 and 36 was scanned to create an STL data set of each tooth. These were used to fabricate n = 8 polyetheretherketone-based root analog implants per group, with 5 groups being fabricated per tooth type. Two groups were additively manufactured using material extrusion. The other groups were milled from differnet polyetheretherketone grades. After artificial ageing, the samples were statically loaded until fracture in order to determine the bending moment. Of the root analog implants in the form of a 31, a white, milled polyetheretherketone grade showed the highest bending moment of 2835.3 ± 509.8 Nmm and an unfilled, additively processed polyetheretherketone grade the lowest. Of the RAIs in the form of a 36, an unfilled, milled polyetheretherketone grade showed the highest bending moment with 29342.6 ± 854.7 Nmm and a white, additively processed polyetheretherketone grade showed the lowest bending moment with 19880.5 ± 7188.6 Nmm. Basically, the results between the additively and subtractively processed groups were significantly different. In terms of mechanical requirements in the oral cavity, one-piece milled polyetheretherketone -based RAIs appear to provide more predictable results than additively manufactured ones. Taken together, our study suggests that more solidly designed one-piece root analog implants made of milled polyetheretherketone in the form of molars appear to be able to withstand the mechanical requirements of the oral cavity.

Journal of BiomechanicsVol. 184
Humboldt-Universität zu Berlin (DE), Xi'an Jiaotong University (CN)
Zero hunger
Openalex Percentile: Top 92%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.