Numerical investigation of the effect of three types of spiral coils on the hydrothermal behavior of fluid flow in a shell and coil heat exchanger

This investigation is specifically centered on quantitatively assessing the heat transfer and fluid movement within a shell and spiral tube heat exchanger comprising three distinct designs. Water was considered as the heat transfer fluid, operating within the spiral coil and the shell. In this setup, the hot fluid circulates inside the coil while the cold fluid is contained within the shell. The research covers a range of Reynolds numbers from 500 to 2000 and is split into two parts. The first part of the study examines the impact of three different spiral coil models and evaluates their thermal performance. In the second part, the best spiral coil is selected based on the findings from the first part. Three different spiral winding pitches (P) are considered: 60 mm, 50 mm, and 40 mm, with the results compared to those of a simple winding. Among the three models analyzed in the first part, model (A) with a special helical coil design exhibited the greatest thermal productivity across different Reynolds numbers. Findings showed that the helical coil with the model (A) design enhances the energy exchange between hot and cold fluid particles owing to the reinforcement of centrifugal force, intensified secondary flow, and improved radial mixing of particles. As a result, this particular coil displayed significant thermal perform effectiveness because of the intensified vortex movement of liquid particles and the thinning of thermal boundary layers. The second part of the study revealed that the thermal performance of the spiral coil with a 60 mm pitch surpassed that of the other two models. At a Reynolds number of 500, it was observed that the thermal performance coefficient increased by 60 % for the model with a 60 mm pitch, 45 % for the model with a 50 mm pitch, and 28.8 % for the model with a 40 mm pitch. This indicates a significant improvement in thermal performance as the pitch size decreases.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-04-06
DOI
https://doi.org/10.1016/j.csite.2025.106078
Citations
8
Primary Topic
Nanofluid Flow and Heat Transfer
Type
article
Field-Weighted Citation Impact
5.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical investigation of the effect of three types of spiral coils on the hydrothermal behavior of fluid flow in a shell and coil heat exchanger

Ahmed Mir, Walid Aich, Saurav Dixit, Rassol Hamed Rasheed et al.
8 citations
Case Studies in Thermal Engineering
Nanofluid Flow and Heat Transfer
5.39
article

Numerical investigation of the effect of three types of spiral coils on the hydrothermal behavior of fluid flow in a shell and coil heat exchanger

Ahmed Mir, Walid Aich, Saurav Dixit, Rassol Hamed Rasheed, Rifaqat Ali, Lioua Kolsi, Pradeep Kumar Singh, Seyed Hossein Hashemi Karouei
article en
8 citations

Abstract

This investigation is specifically centered on quantitatively assessing the heat transfer and fluid movement within a shell and spiral tube heat exchanger comprising three distinct designs. Water was considered as the heat transfer fluid, operating within the spiral coil and the shell. In this setup, the hot fluid circulates inside the coil while the cold fluid is contained within the shell. The research covers a range of Reynolds numbers from 500 to 2000 and is split into two parts. The first part of the study examines the impact of three different spiral coil models and evaluates their thermal performance. In the second part, the best spiral coil is selected based on the findings from the first part. Three different spiral winding pitches (P) are considered: 60 mm, 50 mm, and 40 mm, with the results compared to those of a simple winding. Among the three models analyzed in the first part, model (A) with a special helical coil design exhibited the greatest thermal productivity across different Reynolds numbers. Findings showed that the helical coil with the model (A) design enhances the energy exchange between hot and cold fluid particles owing to the reinforcement of centrifugal force, intensified secondary flow, and improved radial mixing of particles. As a result, this particular coil displayed significant thermal perform effectiveness because of the intensified vortex movement of liquid particles and the thinning of thermal boundary layers. The second part of the study revealed that the thermal performance of the spiral coil with a 60 mm pitch surpassed that of the other two models. At a Reynolds number of 500, it was observed that the thermal performance coefficient increased by 60 % for the model with a 60 mm pitch, 45 % for the model with a 50 mm pitch, and 28.8 % for the model with a 40 mm pitch. This indicates a significant improvement in thermal performance as the pitch size decreases.

Case Studies in Thermal EngineeringVol. 70
Northern Border University (SA), University of Ha'il (SA), University of Warith Al-Anbiyaa, Chitkara University (IN), GLA University (IN), King Khalid University (SA), Babol Noshirvani University of Technology (IR)
Clean water and sanitation
Openalex Percentile: Top 4%
Nanofluid Flow and Heat Transfer
5.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.