Flat slabs without beams are common slab systems due to their simple formwork and ability to accommodate reduced story heights. Reinforced concrete slab-column connections are critical, especially internal connections with the final roof slabs. This research aims to compare the correct and incorrect reinforcing details of internal slabcolumn connections and examine how they affect the connections' behaviour. One of the most common problems in reinforced concrete structures is incorrect reinforcing details of slab-column connections, which is caused by insufficient experience and a lack of quality control. For this reason, numerical research is carried out. FE models for eighteen (18) specimens were developed. Every specimen is modelled with both correct and incorrect reinforcing details for various slab thicknesses of 150, 200, and 250 mm, as well as different concrete grade values of 25 MPa, 35 MPa, and 45 MPa. It was found that using incorrect reinforcing details for internal slab-column connection could decrease the load capacity and increase the deflection.

Authors

Publication Details

Journal
MEJ Mansoura Engineering Journal
Published
2025-01-01
DOI
https://doi.org/10.58491/2735-4202.3271
Citations
1
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Behaviour of the internal RC slab-column connection with both correct and incorrect reinforcing details

Momen M. Ali, Abdelrhman B. Harraz, Walid H. Shalaby
1 citations
MEJ Mansoura Engineering Journal
Structural Behavior of Reinforced Concrete
1.01
article

Behaviour of the internal RC slab-column connection with both correct and incorrect reinforcing details

Momen M. Ali, Abdelrhman B. Harraz, Walid H. Shalaby
article en
1 citations

Abstract

Flat slabs without beams are common slab systems due to their simple formwork and ability to accommodate reduced story heights. Reinforced concrete slab-column connections are critical, especially internal connections with the final roof slabs. This research aims to compare the correct and incorrect reinforcing details of internal slabcolumn connections and examine how they affect the connections' behaviour. One of the most common problems in reinforced concrete structures is incorrect reinforcing details of slab-column connections, which is caused by insufficient experience and a lack of quality control. For this reason, numerical research is carried out. FE models for eighteen (18) specimens were developed. Every specimen is modelled with both correct and incorrect reinforcing details for various slab thicknesses of 150, 200, and 250 mm, as well as different concrete grade values of 25 MPa, 35 MPa, and 45 MPa. It was found that using incorrect reinforcing details for internal slab-column connection could decrease the load capacity and increase the deflection.

MEJ Mansoura Engineering JournalVol. 50(1)
Openalex Percentile: Top 26%
Structural Behavior of Reinforced Concrete
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.