Development of a Novel Nested–RT–LAMP Assay for the Rapid and Accurate Coronavirus Disease‐2019 Diagnosis

<b>Background and Aims:</b> Coronavirus disease 2019 (COVID-19), an emerging life-threatening viral disease, has rapidly spread worldwide, exerting a detrimental impact on public health. We aimed to devise an innovative platform based on the loop-mediated isothermal amplification (LAMP) method, having priorities over real-time PCR (RT-PCR) in terms of sensitivity, specificity, and low running costs. <b>Methods:</b> To develop a novel assay, a new primer set plus four primer sets were designed targeting the N gene of the COVID-19 agent, resulting in the sensitivity reinforcement. The limit of detection (LOD) of the developed approach was determined and compared to those of the standard RT-LAMP and RT-PCR. Two hundred confirmed positive and negative samples initially tested by RT-PCR were recruited to assess the nested-RT-LAMP assay. Furthermore, for the one-step nested-RT-LAMP assay, positive samples were tested directly without the need for RNA extraction. <b>Results:</b> The LOD of nested-RT-LAMP, LAMP, and RT-PCR were 5, 15, and 15 copies/μL, respectively. The findings of the investigation illustrated 100% sensitivity and 98% specificity for both LAMP assays. Moreover, respectively, 94% and 97% sensitivity and specificity were determined regarding the one-step nested-RT-LAMP assay. <b>Conclusion:</b> We offered a novel approach with more sensitivity compared to RT-PCR and common RT-LAMP, not only being a simple, accurate, cost-effective alternative diagnostic tool for RT-PCR but also being able to detect asymptomatic or mildly symptomatic patients more accurately in 2 h by naked eyes.

Authors

Institutions

Publication Details

Journal
Canadian Journal of Infectious Diseases and Medical Microbiology
Published
2025-01-01
DOI
https://doi.org/10.1155/cjid/3343309
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Novel Nested–RT–LAMP Assay for the Rapid and Accurate Coronavirus Disease‐2019 Diagnosis

Razie Ranjbar, Neda Sepahi, Abdolmajid Ghasemian, Ali Ghanbariasad et al.
Canadian Journal of Infectious Diseases and Medical Microbiology
Biosensors and Analytical Detection
article

Development of a Novel Nested–RT–LAMP Assay for the Rapid and Accurate Coronavirus Disease‐2019 Diagnosis

Razie Ranjbar, Neda Sepahi, Abdolmajid Ghasemian, Ali Ghanbariasad, Negin Namavari, Sahar Samsami, Hadi Mirzaei, Yaser Mansoori, Maryam Chenari, Sahar Namavari, Zahra Montaseri
article en

Abstract

<b>Background and Aims:</b> Coronavirus disease 2019 (COVID-19), an emerging life-threatening viral disease, has rapidly spread worldwide, exerting a detrimental impact on public health. We aimed to devise an innovative platform based on the loop-mediated isothermal amplification (LAMP) method, having priorities over real-time PCR (RT-PCR) in terms of sensitivity, specificity, and low running costs. <b>Methods:</b> To develop a novel assay, a new primer set plus four primer sets were designed targeting the N gene of the COVID-19 agent, resulting in the sensitivity reinforcement. The limit of detection (LOD) of the developed approach was determined and compared to those of the standard RT-LAMP and RT-PCR. Two hundred confirmed positive and negative samples initially tested by RT-PCR were recruited to assess the nested-RT-LAMP assay. Furthermore, for the one-step nested-RT-LAMP assay, positive samples were tested directly without the need for RNA extraction. <b>Results:</b> The LOD of nested-RT-LAMP, LAMP, and RT-PCR were 5, 15, and 15 copies/μL, respectively. The findings of the investigation illustrated 100% sensitivity and 98% specificity for both LAMP assays. Moreover, respectively, 94% and 97% sensitivity and specificity were determined regarding the one-step nested-RT-LAMP assay. <b>Conclusion:</b> We offered a novel approach with more sensitivity compared to RT-PCR and common RT-LAMP, not only being a simple, accurate, cost-effective alternative diagnostic tool for RT-PCR but also being able to detect asymptomatic or mildly symptomatic patients more accurately in 2 h by naked eyes.

Canadian Journal of Infectious Diseases and Medical MicrobiologyVol. 2025(1)
St. George's University (GD), Zabol University of Medical Sciences (IR), Fasa University of Medical Sciences (IR), Tehran University of Medical Sciences (IR)
Fasa University of Medical Sciences, Zabol University of Medical Sciences
Openalex Percentile: Top 94%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.