Wire cerclages as part of osteosynthesis- examination for optimal placement

Wire cerclages are commonly used during osteosynthesis of bone shaft fractures. To date, there is no study that examines the intraoperative utilization by different experienced surgeons in terms of reproducibility. This study aimed to test the hypothesis that a double-looped-cerclage is superior to a single-looped-cerclage in terms of reproducibility and uniform contact pressure. 27 medical doctors working in orthopedics/trauma surgery took part in this study. A wire cerclage was applied to a bovine bone half-shell model mounted on a dynamometer. A single-looped-cerclage and a double-looped-cerclage were applied alternately 5 times each. The applied force before modelling the cerclage knot on the bone (fbM) and the applied force after modelling on the bone (faM) were recorded in a blinded manner. The median faM in a double-looped-cerclage was 375 N (IQR 230-531 N) and therefore significantly higher (p < 0.05) than in a single-looped-cerclage (150 N (IQR 83-232 N)). As a result of applying the cerclage knot to the bone, the force decreased by an average of 80 N, with no differences in single-looped-cerclage or double-looped-cerclage. (Force-loss single-looped-cerclage 84 N (IQR 35.75-132 N); Force-loss double-looped-cerclage 82 N (IQR 46-116 N). The quartile dispersion coefficient as an expression of dispersion for the 5 applications each was 0.7121 (IQR 0.6544-0.8979) for single-looped-cerclage and was significantly higher than for double-looped-cerclage 0.3876 (IQR 0.2376-0.5184). In summary, this study showed that a double-looped-cerclage was superior to a single-looped-cerclage when used intraoperatively in terms of contact pressure and reproducibility.

Authors

Institutions

Publication Details

Journal
Archives of Orthopaedic and Trauma Surgery
Published
2025-04-05
DOI
https://doi.org/10.1007/s00402-025-05795-y
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wire cerclages as part of osteosynthesis- examination for optimal placement

Steffen Ruchholtz, Martin Bäumlein, Christopher Bliemel, René Aigner et al.
Archives of Orthopaedic and Trauma Surgery
Bone fractures and treatments
article

Wire cerclages as part of osteosynthesis- examination for optimal placement

Steffen Ruchholtz, Martin Bäumlein, Christopher Bliemel, René Aigner, Tobias Schürholz, Denis Visser
article en

Abstract

Wire cerclages are commonly used during osteosynthesis of bone shaft fractures. To date, there is no study that examines the intraoperative utilization by different experienced surgeons in terms of reproducibility. This study aimed to test the hypothesis that a double-looped-cerclage is superior to a single-looped-cerclage in terms of reproducibility and uniform contact pressure. 27 medical doctors working in orthopedics/trauma surgery took part in this study. A wire cerclage was applied to a bovine bone half-shell model mounted on a dynamometer. A single-looped-cerclage and a double-looped-cerclage were applied alternately 5 times each. The applied force before modelling the cerclage knot on the bone (fbM) and the applied force after modelling on the bone (faM) were recorded in a blinded manner. The median faM in a double-looped-cerclage was 375 N (IQR 230-531 N) and therefore significantly higher (p < 0.05) than in a single-looped-cerclage (150 N (IQR 83-232 N)). As a result of applying the cerclage knot to the bone, the force decreased by an average of 80 N, with no differences in single-looped-cerclage or double-looped-cerclage. (Force-loss single-looped-cerclage 84 N (IQR 35.75-132 N); Force-loss double-looped-cerclage 82 N (IQR 46-116 N). The quartile dispersion coefficient as an expression of dispersion for the 5 applications each was 0.7121 (IQR 0.6544-0.8979) for single-looped-cerclage and was significantly higher than for double-looped-cerclage 0.3876 (IQR 0.2376-0.5184). In summary, this study showed that a double-looped-cerclage was superior to a single-looped-cerclage when used intraoperatively in terms of contact pressure and reproducibility.

Archives of Orthopaedic and Trauma SurgeryVol. 145(1)
Philipps University of Marburg (DE), Universitätsklinikum Gießen und Marburg (DE)
Philipps-Universität Marburg
Good health and well-being
Openalex Percentile: Top 90%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.