Towards Large Diameter Transmit Coils for 7‐T Head Imaging: A Detailed Comparison of a Set of Transmit Element Design Concepts

Many different transmit (Tx) coil concepts and designs for 7-T magnetic resonance imaging of the head have been proposed. Most of them are placed close to the head and in combination with the receive coils creating a helmet-like structure. This limits the space for additional equipment for external stimuli. A large diameter transmit coil can increase the ease using supplementary measurement devices. Therefore, this study systematically evaluated nine different Tx elements regarding their performance within a large diameter transmit coil with a diameter <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mo>></mml:mo></mml:mrow> <mml:annotation>$$ > $$</mml:annotation></mml:semantics> </mml:math> 350 mm. Each Tx element was examined regarding its power and specific absorption rate (SAR) efficiencies, its loading dependence, intrinsic decoupling, and its radio frequency (RF) shimming capability. Additionally, an experimental validation of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mo>|</mml:mo> <mml:msubsup><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mtext>1</mml:mtext></mml:mrow> <mml:mrow><mml:mtext>+</mml:mtext></mml:mrow> </mml:msubsup> <mml:mo>|</mml:mo></mml:mrow> <mml:annotation>$$ \mid {B}_1^{+}\mid $$</mml:annotation></mml:semantics> </mml:math> -maps was performed. The loop-based Tx elements (circular and rectangular loop) provided the highest power and SAR efficiency with at least 15.5% and 21.2% higher efficiencies for a single channel and 22.1% and 18.0% for the eight-channel array, respectively. In terms of voxel-wise power efficiency, the circular loop was the superior Tx element type within most of the head. Looking at the voxel-wise SAR efficiency, the loop-based elements manifest themselves as the most efficient type within most of the central brain. The mutual coupling was lowest for the passively fed dipole ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mo>-</mml:mo></mml:mrow> <mml:annotation>$$ - $$</mml:annotation></mml:semantics> </mml:math> 31.23 dB). The highest RF shimming capability in terms of sum of normalized singular values was calculated for the rectangular (4.21) and the circular loop (4.36), whereby the L-curve results showed that the arrays have only minor <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mo>|</mml:mo> <mml:msubsup><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mtext>1</mml:mtext></mml:mrow> <mml:mrow><mml:mtext>+</mml:mtext></mml:mrow> </mml:msubsup> <mml:mo>|</mml:mo></mml:mrow> <mml:annotation>$$ \mid {B}_1^{+}\mid $$</mml:annotation></mml:semantics> </mml:math> shimming performance differences for the transversal slice. For the hippocampus, the meander element provided the highest overall homogeneity with a minimal coefficient of variation (CoV) of 5.1%. This work provides extensive and unique data for single and eight-channel Tx elements applying common performance benchmarks and enables further discourse on multi-channel evaluations towards large diameter Tx coils at 7-T head imaging. On the bases of the provided results, the preferable Tx element type for this specific application is loop-based.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2025-04-05
DOI
https://doi.org/10.1002/nbm.70030
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards Large Diameter Transmit Coils for 7‐T Head Imaging: A Detailed Comparison of a Set of Transmit Element Design Concepts

Stephan Orzada, Max Joris Hubmann, Robert Kowal, Holger Maune et al.
NMR in Biomedicine
Advanced MRI Techniques and Applications
article

Towards Large Diameter Transmit Coils for 7‐T Head Imaging: A Detailed Comparison of a Set of Transmit Element Design Concepts

Stephan Orzada, Max Joris Hubmann, Robert Kowal, Holger Maune, Oliver Speck, Johannes A. Grimm
article en

Abstract

Many different transmit (Tx) coil concepts and designs for 7-T magnetic resonance imaging of the head have been proposed. Most of them are placed close to the head and in combination with the receive coils creating a helmet-like structure. This limits the space for additional equipment for external stimuli. A large diameter transmit coil can increase the ease using supplementary measurement devices. Therefore, this study systematically evaluated nine different Tx elements regarding their performance within a large diameter transmit coil with a diameter <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mo>></mml:mo></mml:mrow> <mml:annotation>$$ > $$</mml:annotation></mml:semantics> </mml:math> 350 mm. Each Tx element was examined regarding its power and specific absorption rate (SAR) efficiencies, its loading dependence, intrinsic decoupling, and its radio frequency (RF) shimming capability. Additionally, an experimental validation of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mo>|</mml:mo> <mml:msubsup><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mtext>1</mml:mtext></mml:mrow> <mml:mrow><mml:mtext>+</mml:mtext></mml:mrow> </mml:msubsup> <mml:mo>|</mml:mo></mml:mrow> <mml:annotation>$$ \mid {B}_1^{+}\mid $$</mml:annotation></mml:semantics> </mml:math> -maps was performed. The loop-based Tx elements (circular and rectangular loop) provided the highest power and SAR efficiency with at least 15.5% and 21.2% higher efficiencies for a single channel and 22.1% and 18.0% for the eight-channel array, respectively. In terms of voxel-wise power efficiency, the circular loop was the superior Tx element type within most of the head. Looking at the voxel-wise SAR efficiency, the loop-based elements manifest themselves as the most efficient type within most of the central brain. The mutual coupling was lowest for the passively fed dipole ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mo>-</mml:mo></mml:mrow> <mml:annotation>$$ - $$</mml:annotation></mml:semantics> </mml:math> 31.23 dB). The highest RF shimming capability in terms of sum of normalized singular values was calculated for the rectangular (4.21) and the circular loop (4.36), whereby the L-curve results showed that the arrays have only minor <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mo>|</mml:mo> <mml:msubsup><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mtext>1</mml:mtext></mml:mrow> <mml:mrow><mml:mtext>+</mml:mtext></mml:mrow> </mml:msubsup> <mml:mo>|</mml:mo></mml:mrow> <mml:annotation>$$ \mid {B}_1^{+}\mid $$</mml:annotation></mml:semantics> </mml:math> shimming performance differences for the transversal slice. For the hippocampus, the meander element provided the highest overall homogeneity with a minimal coefficient of variation (CoV) of 5.1%. This work provides extensive and unique data for single and eight-channel Tx elements applying common performance benchmarks and enables further discourse on multi-channel evaluations towards large diameter Tx coils at 7-T head imaging. On the bases of the provided results, the preferable Tx element type for this specific application is loop-based.

NMR in BiomedicineVol. 38(5)
German Cancer Research Center (DE), Heidelberg University (DE), Siemens Healthineers (Germany) (DE), Otto-von-Guericke-Universität Magdeburg (DE)
Bundesministerium für Bildung und Forschung, European Regional Development Fund
Affordable and clean energy
Openalex Percentile: Top 90%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.