Theta-gamma phase-amplitude coupling as a promising neurophysiological biomarker for evaluating the efficacy of low-intensity focused ultrasound stimulation on vascular dementia treatment

Low-intensity focused ultrasound stimulation (LIFUS) has garnered attention for its potential in vascular dementia (VD) treatment. However, the lack of sufficient data supporting its efficacy and elucidating its mechanisms of action limits its further clinical translation and application. Considerable researches support the idea that LIFUS can improve the disturbance of neural oscillation modes caused by a variety of neurological diseases. However, the effect of LIFUS on neural oscillation modes in VD remains unclear. Therefore, this study aims to investigate the therapeutic effects of LIFUS on neural oscillation modes in VD. To achieve this purpose, the VD model was established via the bilateral common carotid artery occlusion, followed by two weeks of LIFUS treatment targeting the bilateral hippocampus. The therapeutic effects of LIFUS were evaluated by behavioral tests and cerebral blood flow measurement. Electrophysiological signals were recorded from the hippocampal CA1 and CA3 and medial prefrontal cortex (mPFC). The results indicated LIFUS could effectively improve cognitive dysfunction in VD rats. The underlying electrophysiological mechanisms involved the restoration of phase-amplitude coupling (PAC) of theta-gamma oscillations within both the CA3-CA1 local circuit and the hippocampus-mPFC cross-brain circuit. Classification results based on PAC characteristics suggested that PAC metrics are effective for evaluating the efficacy of LIFUS in treating VD, with optimal recognition performance observed in the hippocampus-mPFC cross-brain circuit. Our findings provide neuroelectrophysiological insights into the mechanisms of LIFUS in VD treatment and propose a promising diagnostic biomarker for evaluating LIFUS efficacy in future applications.

Authors

Institutions

Publication Details

Journal
Experimental Neurology
Published
2025-04-05
DOI
https://doi.org/10.1016/j.expneurol.2025.115237
Citations
1
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Theta-gamma phase-amplitude coupling as a promising neurophysiological biomarker for evaluating the efficacy of low-intensity focused ultrasound stimulation on vascular dementia treatment

Chenguang Zheng, Jing Ren, Dong Ming, Qiuquan Cai et al.
1 citations
Experimental Neurology
Ultrasound and Hyperthermia Applications
0.67
article

Theta-gamma phase-amplitude coupling as a promising neurophysiological biomarker for evaluating the efficacy of low-intensity focused ultrasound stimulation on vascular dementia treatment

Chenguang Zheng, Jing Ren, Dong Ming, Qiuquan Cai, Yutao Tian, Jiajia Yang, Ling Wang, Faqi Wang, Qing Yang, Rong Liang
article en
1 citations

Abstract

Low-intensity focused ultrasound stimulation (LIFUS) has garnered attention for its potential in vascular dementia (VD) treatment. However, the lack of sufficient data supporting its efficacy and elucidating its mechanisms of action limits its further clinical translation and application. Considerable researches support the idea that LIFUS can improve the disturbance of neural oscillation modes caused by a variety of neurological diseases. However, the effect of LIFUS on neural oscillation modes in VD remains unclear. Therefore, this study aims to investigate the therapeutic effects of LIFUS on neural oscillation modes in VD. To achieve this purpose, the VD model was established via the bilateral common carotid artery occlusion, followed by two weeks of LIFUS treatment targeting the bilateral hippocampus. The therapeutic effects of LIFUS were evaluated by behavioral tests and cerebral blood flow measurement. Electrophysiological signals were recorded from the hippocampal CA1 and CA3 and medial prefrontal cortex (mPFC). The results indicated LIFUS could effectively improve cognitive dysfunction in VD rats. The underlying electrophysiological mechanisms involved the restoration of phase-amplitude coupling (PAC) of theta-gamma oscillations within both the CA3-CA1 local circuit and the hippocampus-mPFC cross-brain circuit. Classification results based on PAC characteristics suggested that PAC metrics are effective for evaluating the efficacy of LIFUS in treating VD, with optimal recognition performance observed in the hippocampus-mPFC cross-brain circuit. Our findings provide neuroelectrophysiological insights into the mechanisms of LIFUS in VD treatment and propose a promising diagnostic biomarker for evaluating LIFUS efficacy in future applications.

Experimental NeurologyVol. 389
Tianjin University (CN), Tianjin Medical University (CN)
Openalex Percentile: Top 33%
Ultrasound and Hyperthermia Applications
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.