Accuracy Comparison of Guided Implant Placement Between Tooth and Mucosal Supported Stereolithographic Models in the Maxillary Arch. (An experimental study)

Objective: Employing stereolithographic surgical guides is highly beneficial for enhancing and analyzing implant position accuracy. This study aimed to differentiate between the accuracy of implant position with two different models employing guided surgery based on the support level (tooth-mucosa). Methods: A total of 80 implants were virtually planned and surgically positioned on twenty maxillary dental arches utilizing two distinct stereolithographic models (40 using tissue and 40 using tooth supported surgical guides). Four virtual implants were planned for each dental arch in the implant planning software. Accuracy measurement was made possible by matching process within the software between virtually planned and actually positioned implants, utilizing radiographic markers in the maxillary arch as matching points. Measuring was carried out at the center of the implant hexagon, apex and angle deviations. Results: The overall difference between tooth- and mucosa-supported surgical models for angular and apical deviations was not statistically significant except for hexagonal deviation, which showed (P <0.001), where the mean distance deviations at the hexagons and apices level showed 1.24 ± 0.38 mm and 1.22 ± 0.51 mm for the guides supported by teeth, and 1.83 ±1.09 mm and 1.24 ±0.69 mm for the guides supported by mucosa. The angular deviation for tooth- and mucosa-supported guides measured 4.38 ± 3.22 and 3.9 ±2.61 degrees, respectively. Conclusions: Based on this study’s results, it is concluded that there is a correlation between implant placement accuracy and the type of surgical guide support. Specifically, surgical guides supported by mucosa showed lower accuracy at the hexagon level compared to those supported by tooth structures. The resiliency of the mucosa may influence implant placement accuracy and subsequent prosthetic plan.

Authors

Institutions

Publication Details

Journal
Sulaimani dental journal
Published
2025-04-01
DOI
https://doi.org/10.17656/sdj.10200
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy Comparison of Guided Implant Placement Between Tooth and Mucosal Supported Stereolithographic Models in the Maxillary Arch. (An experimental study)

Mohammed Rasheed, Bayad Jaza Mahmood
Sulaimani dental journal
Dental Implant Techniques and Outcomes
article

Accuracy Comparison of Guided Implant Placement Between Tooth and Mucosal Supported Stereolithographic Models in the Maxillary Arch. (An experimental study)

Mohammed Rasheed, Bayad Jaza Mahmood
article en

Abstract

Objective: Employing stereolithographic surgical guides is highly beneficial for enhancing and analyzing implant position accuracy. This study aimed to differentiate between the accuracy of implant position with two different models employing guided surgery based on the support level (tooth-mucosa). Methods: A total of 80 implants were virtually planned and surgically positioned on twenty maxillary dental arches utilizing two distinct stereolithographic models (40 using tissue and 40 using tooth supported surgical guides). Four virtual implants were planned for each dental arch in the implant planning software. Accuracy measurement was made possible by matching process within the software between virtually planned and actually positioned implants, utilizing radiographic markers in the maxillary arch as matching points. Measuring was carried out at the center of the implant hexagon, apex and angle deviations. Results: The overall difference between tooth- and mucosa-supported surgical models for angular and apical deviations was not statistically significant except for hexagonal deviation, which showed (P <0.001), where the mean distance deviations at the hexagons and apices level showed 1.24 ± 0.38 mm and 1.22 ± 0.51 mm for the guides supported by teeth, and 1.83 ±1.09 mm and 1.24 ±0.69 mm for the guides supported by mucosa. The angular deviation for tooth- and mucosa-supported guides measured 4.38 ± 3.22 and 3.9 ±2.61 degrees, respectively. Conclusions: Based on this study’s results, it is concluded that there is a correlation between implant placement accuracy and the type of surgical guide support. Specifically, surgical guides supported by mucosa showed lower accuracy at the hexagon level compared to those supported by tooth structures. The resiliency of the mucosa may influence implant placement accuracy and subsequent prosthetic plan.

Sulaimani dental journalVol. 12(1)
University of Sulaimani (IQ)
Openalex Percentile: Top 91%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accuracy Comparison of Guided Implant Placement Between Tooth and Mucosal Supported Stereolithographic Models in the Maxillary Arch. (An experimental study) — Mohammed Rasheed, Bayad Jaza Mahmood · Sulaimani dental journal (2025) | TGRS Research Map | TGRS