Internal Standard Utilization Strategies for Quantitative Paper Spray Mass Spectrometry

Premixing internal standards (ISTD) with liquid samples prior to paper spray mass spectrometry (PS-MS) analysis consumes unnecessary amounts of ISTD and is not feasible for all sample types and applications. Depositing ISTD directly on the paper independently from sample has been successfully employed in the literature but can negatively affect quantitative performance. We evaluated different ISTD utilization strategies using drugs of misuse as test analytes to investigate the sources of irreproducibility and bias. Performance was assessed using both pre- and postdeposited ISTD (relative to sample loading) at different volumes with a constant final mass loading of 1 ng of each ISTD compound. Precision and accuracy were lower when using independently deposited ISTD compared to premixed ISTD (average CV = 18% vs 1% and average |bias| = 61% vs 5% for independently deposited ISTD and premixed ISTD, respectively). The use of a robotic liquid sample handling system to deposit ISTD was compared with results obtained via manually pipetting. Predeposited ISTD performed best at lower deposition volumes when a robotic liquid handler was used (average CV = 8% and 11% for 2 and 10 μL, respectively), but manual pipetting of low volume ISTD depositions performed poorly. Postdeposited ISTD was inferior to predeposited ISTD strategies, favoring larger deposition volumes regardless of deposition method (average CV = 22% and 16% for 2 and 10 μL, respectively). Systematic biases associated with each ISTD utilization strategy were effectively corrected for using strategy-matched calibrations, and AAFS (American Academy of Forensic Sciences) accuracy and precision requirements were achieved in almost all cases.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2025-04-05
DOI
https://doi.org/10.1021/jasms.5c00036
Citations
6
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
4.54

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Internal Standard Utilization Strategies for Quantitative Paper Spray Mass Spectrometry

Lucas R. Abruzzi, John-Clare Laxton, Taelor M. Zarkovic, Chris G. Gill
6 citations
Journal of the American Society for Mass Spectrometry
Mass Spectrometry Techniques and Applications
4.54
article

Internal Standard Utilization Strategies for Quantitative Paper Spray Mass Spectrometry

Lucas R. Abruzzi, John-Clare Laxton, Taelor M. Zarkovic, Chris G. Gill
article en
6 citations

Abstract

Premixing internal standards (ISTD) with liquid samples prior to paper spray mass spectrometry (PS-MS) analysis consumes unnecessary amounts of ISTD and is not feasible for all sample types and applications. Depositing ISTD directly on the paper independently from sample has been successfully employed in the literature but can negatively affect quantitative performance. We evaluated different ISTD utilization strategies using drugs of misuse as test analytes to investigate the sources of irreproducibility and bias. Performance was assessed using both pre- and postdeposited ISTD (relative to sample loading) at different volumes with a constant final mass loading of 1 ng of each ISTD compound. Precision and accuracy were lower when using independently deposited ISTD compared to premixed ISTD (average CV = 18% vs 1% and average |bias| = 61% vs 5% for independently deposited ISTD and premixed ISTD, respectively). The use of a robotic liquid sample handling system to deposit ISTD was compared with results obtained via manually pipetting. Predeposited ISTD performed best at lower deposition volumes when a robotic liquid handler was used (average CV = 8% and 11% for 2 and 10 μL, respectively), but manual pipetting of low volume ISTD depositions performed poorly. Postdeposited ISTD was inferior to predeposited ISTD strategies, favoring larger deposition volumes regardless of deposition method (average CV = 22% and 16% for 2 and 10 μL, respectively). Systematic biases associated with each ISTD utilization strategy were effectively corrected for using strategy-matched calibrations, and AAFS (American Academy of Forensic Sciences) accuracy and precision requirements were achieved in almost all cases.

Journal of the American Society for Mass SpectrometryVol. 36(5)
University of Washington (US), University of Victoria (CA), Canadian Centre on Substance Use and Addiction (CA), Vancouver Island University (CA)
Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 5%
Mass Spectrometry Techniques and Applications
4.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.