Development of dynamic gas generation system for ultratrace amounts of acetone at parts-per-trillion levels with low temperature permeation method

Different types of gas sensing devices have been developed to monitor trace amounts of volatile compounds emitted from exhalation, human skin, building materials, and atmospheric chemical reactions, etc.. In particular, the recent progress in transdermal sensing techniques could enable detection of trace amounts of biochemicals at parts per trillion (ppt) levels. Preparation of known-concentration gases at that level is very important to accurately evaluate and calibrate these sensing devices. We developed an accurate dynamic gas generation system with a permeation method at the ppt level for acetone, a well-known biomarker of diabetes and obese, which consists of an accurately low-temperature controlled tube chamber with a thermostat, mass flow controller, custom-built acetone permeation tube with a low permeability, and nitrogen carrier gas. With the system, the permeation rate of acetone was 0.409 ± 0.011 ng min−1 (k = 2). The calculated concentrations obtained from the permeation rate and three setting points of the carrier gas flow rate (20.26, 38.26, and 74.86 pptv) agreed with those analyzed by the dinitrophenylhydrazine derivatization–high-performance liquid chromatography method (20.33, 37.85, and 81.08 pptv) within the level of each expanded uncertainty of 3.0–5.1%. The temperature dependence of the permeation tube obeyed an Arrhenius-type law. The error related to temperature change in the permeation rate in the system was estimated to be below 0.1% of the permeation rate. This study demonstrates an accurate gas preparation with an ultratrace amount of acetone gas using the dynamic low temperature permeation method.

Authors

Institutions

Publication Details

Journal
Discover Applied Sciences
Published
2025-04-03
DOI
https://doi.org/10.1007/s42452-025-06722-x
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of dynamic gas generation system for ultratrace amounts of acetone at parts-per-trillion levels with low temperature permeation method

Takahiro Arakawa, Reiji Aoyagi, Yoshika Sekine, Kenta Iitani et al.
Discover Applied Sciences
Advanced Chemical Sensor Technologies
article

Development of dynamic gas generation system for ultratrace amounts of acetone at parts-per-trillion levels with low temperature permeation method

Takahiro Arakawa, Reiji Aoyagi, Yoshika Sekine, Kenta Iitani, Yuichiro Kaifuku, Kohji Mitsubayashi
article en

Abstract

Different types of gas sensing devices have been developed to monitor trace amounts of volatile compounds emitted from exhalation, human skin, building materials, and atmospheric chemical reactions, etc.. In particular, the recent progress in transdermal sensing techniques could enable detection of trace amounts of biochemicals at parts per trillion (ppt) levels. Preparation of known-concentration gases at that level is very important to accurately evaluate and calibrate these sensing devices. We developed an accurate dynamic gas generation system with a permeation method at the ppt level for acetone, a well-known biomarker of diabetes and obese, which consists of an accurately low-temperature controlled tube chamber with a thermostat, mass flow controller, custom-built acetone permeation tube with a low permeability, and nitrogen carrier gas. With the system, the permeation rate of acetone was 0.409 ± 0.011 ng min−1 (k = 2). The calculated concentrations obtained from the permeation rate and three setting points of the carrier gas flow rate (20.26, 38.26, and 74.86 pptv) agreed with those analyzed by the dinitrophenylhydrazine derivatization–high-performance liquid chromatography method (20.33, 37.85, and 81.08 pptv) within the level of each expanded uncertainty of 3.0–5.1%. The temperature dependence of the permeation tube obeyed an Arrhenius-type law. The error related to temperature change in the permeation rate in the system was estimated to be below 0.1% of the permeation rate. This study demonstrates an accurate gas preparation with an ultratrace amount of acetone gas using the dynamic low temperature permeation method.

Discover Applied SciencesVol. 7(4)
Tokai University (JP), Tokyo University of Technology (JP), Japan Space Forum (JP), ID Pharma (Japan) (JP)
New Energy and Industrial Technology Development Organization
Openalex Percentile: Top 94%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.