Pushing the sensitivity boundaries of X-band EPR cryoprobe using a fast microwave switch

We present a new design of an X-band EPR cryoprobe based on a fast microwave switch and a cryogenic low-noise microwave amplifier that are placed close to the sample in the same cryostat. The probehead supports high-power (100 W) pulsed EPR experiments and is compatible with standard EPR resonators and samples. In contrast to the directional coupler design of the EPR cryoprobe reported previously, the fast microwave switch fully isolates the microwave amplifier from input thermal noise without microwave power suppression allowing us to approach the sensitivity limit of cryoprobes for pulsed EPR experiments. We benchmark the performance of our cryoprobe setup against a standard commercial EPR instrument revealing a significant sensitivity improvement, which reduces the measurement time by a factor of about 250 × at 6 K sample temperature. We also show that the sensitivity of our new X-band cryoprobe design matches that of a standard Q-band setup for double electron–electron resonance experiments. • We developed a pulsed X-band EPR cryoprobe incorporating a fast microwave switch and a cryogenic low-noise microwave preamplifier. • The sample access and resonator tuning of our cryoprobe is the same as in typical X-band EPR. • The cryoprobe supports pulsed EPR experiments at 100 W of microwave power. • Our setup approaches the sensitivity limit of cryoprobes for pulsed EPR experiments. • The sensitivity of our setup almost matches that of a standard commercial Q-band setup for DEER experiments.

Authors

Institutions

Publication Details

Journal
Journal of Magnetic Resonance Open
Published
2025-04-05
DOI
https://doi.org/10.1016/j.jmro.2025.100196
Citations
2
Primary Topic
Electron Spin Resonance Studies
Type
article
Field-Weighted Citation Impact
3.27

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pushing the sensitivity boundaries of X-band EPR cryoprobe using a fast microwave switch

Alice M. Bowen, Gediminas Usevičius, Vidmantas Kalendra, James O’Sullivan et al.
2 citations
Journal of Magnetic Resonance Open
Electron Spin Resonance Studies
3.27
article

Pushing the sensitivity boundaries of X-band EPR cryoprobe using a fast microwave switch

Alice M. Bowen, Gediminas Usevičius, Vidmantas Kalendra, James O’Sullivan, Mantas Šimėnas, John J. L. Morton, Adam Brookfield, J. Banys, Uršulė Tarvydytė
article en
2 citations

Abstract

We present a new design of an X-band EPR cryoprobe based on a fast microwave switch and a cryogenic low-noise microwave amplifier that are placed close to the sample in the same cryostat. The probehead supports high-power (100 W) pulsed EPR experiments and is compatible with standard EPR resonators and samples. In contrast to the directional coupler design of the EPR cryoprobe reported previously, the fast microwave switch fully isolates the microwave amplifier from input thermal noise without microwave power suppression allowing us to approach the sensitivity limit of cryoprobes for pulsed EPR experiments. We benchmark the performance of our cryoprobe setup against a standard commercial EPR instrument revealing a significant sensitivity improvement, which reduces the measurement time by a factor of about 250 × at 6 K sample temperature. We also show that the sensitivity of our new X-band cryoprobe design matches that of a standard Q-band setup for double electron–electron resonance experiments. • We developed a pulsed X-band EPR cryoprobe incorporating a fast microwave switch and a cryogenic low-noise microwave preamplifier. • The sample access and resonator tuning of our cryoprobe is the same as in typical X-band EPR. • The cryoprobe supports pulsed EPR experiments at 100 W of microwave power. • Our setup approaches the sensitivity limit of cryoprobes for pulsed EPR experiments. • The sensitivity of our setup almost matches that of a standard commercial Q-band setup for DEER experiments.

Journal of Magnetic Resonance OpenVol. 23
Vilnius University (LT), London Centre for Nanotechnology (GB), University of Manchester (GB), University College London (GB)
Engineering and Physical Sciences Research Council
Openalex Percentile: Top 9%
Electron Spin Resonance Studies
3.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.