Intelligent Controller Based Shunt Active Power Filter for Enhancement of Power Quality Problems

Power Quality is a major concern now. It depends on voltage, current, and frequency parameters. Power quality issues is defined as “any occurrence manifested in current, voltage, and frequency deviations that results in damage, upset or failure of end-use equipments. The excessive use of non-linear loads causes the power quality To mitigate this Power quality issue a Shunt Active Power Filter is used. It produces compensating current which is equal and phase opposition to the harmonic currents. The switching pulses are produced by the hysteresis current controller. This paper gives detailed analysis of study on the Id-Iq control scheme. This control scheme is carried out by using matlab / simulink Toolbox and Simulation results are observed. Key Words: power quality, shunt active filter, hysteresis current controller, non-linear load, d-q Method

Authors

Publication Details

Journal
INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT
Published
2025-04-05
DOI
https://doi.org/10.55041/ijsrem43830
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intelligent Controller Based Shunt Active Power Filter for Enhancement of Power Quality Problems

Ms.R. Bhuvaneswari, M J Raghavendra, Ms.P. Praphulla Gayathri, Mounika Sriram
INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT
Power Quality and Harmonics
article

Intelligent Controller Based Shunt Active Power Filter for Enhancement of Power Quality Problems

Ms.R. Bhuvaneswari, M J Raghavendra, Ms.P. Praphulla Gayathri, Mounika Sriram
article en

Abstract

Power Quality is a major concern now. It depends on voltage, current, and frequency parameters. Power quality issues is defined as “any occurrence manifested in current, voltage, and frequency deviations that results in damage, upset or failure of end-use equipments. The excessive use of non-linear loads causes the power quality To mitigate this Power quality issue a Shunt Active Power Filter is used. It produces compensating current which is equal and phase opposition to the harmonic currents. The switching pulses are produced by the hysteresis current controller. This paper gives detailed analysis of study on the Id-Iq control scheme. This control scheme is carried out by using matlab / simulink Toolbox and Simulation results are observed. Key Words: power quality, shunt active filter, hysteresis current controller, non-linear load, d-q Method

INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENTVol. 09(04)
Openalex Percentile: Top 95%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.