Dynamic bond behavior of fiber reinforced plastic anchor post‐installed low‐strength concrete under different strain rates

Abstract To investigate the bond–slip behavior of post‐installed adhesive FRP anchor in concrete (PIA‐FRPA‐C) under different strain rates. This paper first compares and analyzes the influence of adhesive type and FRP anchor material type on the bond behavior of specimens through pull‐out experiments. Then, a study is conducted on the pull‐out performance of PIA‐GFRPA‐C with different strain rates and anchorage lengths using epoxy adhesive and glass FRP anchor combined with experiments and numerical simulations. The pull‐out load slip curves and axial stress distribution characteristics of specimens under different strain rates and anchorage lengths are analyzed, the stress transfer mechanism and failure mechanism of the specimens are revealed, and the dynamic increase factor of the average dynamic bond strength and slip of the specimens are determined. An average dynamic pull‐out load prediction formula and an average dynamic bond–slip model are proposed and established. This study can provide a basis for improving the dynamic mechanical properties of concrete structures.

Authors

Institutions

Publication Details

Journal
Structural Concrete
Published
2025-04-04
DOI
https://doi.org/10.1002/suco.70074
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic bond behavior of fiber reinforced plastic anchor post‐installed low‐strength concrete under different strain rates

Wenlong Huo, Xiaohua Wang
Structural Concrete
Structural Behavior of Reinforced Concrete
article

Dynamic bond behavior of fiber reinforced plastic anchor post‐installed low‐strength concrete under different strain rates

Wenlong Huo, Xiaohua Wang
article en

Abstract

Abstract To investigate the bond–slip behavior of post‐installed adhesive FRP anchor in concrete (PIA‐FRPA‐C) under different strain rates. This paper first compares and analyzes the influence of adhesive type and FRP anchor material type on the bond behavior of specimens through pull‐out experiments. Then, a study is conducted on the pull‐out performance of PIA‐GFRPA‐C with different strain rates and anchorage lengths using epoxy adhesive and glass FRP anchor combined with experiments and numerical simulations. The pull‐out load slip curves and axial stress distribution characteristics of specimens under different strain rates and anchorage lengths are analyzed, the stress transfer mechanism and failure mechanism of the specimens are revealed, and the dynamic increase factor of the average dynamic bond strength and slip of the specimens are determined. An average dynamic pull‐out load prediction formula and an average dynamic bond–slip model are proposed and established. This study can provide a basis for improving the dynamic mechanical properties of concrete structures.

Structural ConcreteVol. 26(5)
Tianjin University (CN), Yellow River Institute of Hydraulic Research (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 94%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.