An extension to the OVH concept for knowledge‐based dose volume histogram prediction in lung tumor volumetric‐modulated arc therapy
The combination of OZH and OVH was suitable for building a knowledge-based automated DVH prediction module. Implementing this method into the clinical workflow of treatment planning will contribute to advancing the quality of VMAT plans.