Comparative Evaluation of Peri-implant Strain Generated by Implant-supported Crowns Fabricated with Different Restorative Materials: An In Vitro Study

Purpose: To evaluate and compare peri-implant strain generated by polyetheretherketone (PEEK), zirconia, and porcelain-fused-to-metal (PFM) screw- and cement-retained implant-supported crowns using strain gauges. Materials and methods: A 4 × 12 mm implant (Dentium) was placed in a polymethyl methacrylate (PMMA) block. A prefabricated standard abutment was screwed onto the implant and scanned using a lab scanner. Thirty crowns for the three study groups (<i>n</i> = 10 each), namely PEEK, zirconia, and PFM, were fabricated and screwed onto the implant. Four strain gauges were bonded on the test block around the implant neck at buccal, lingual, mesial, and distal locations. An axial load of 250 N was applied in the center of the crown using a universal testing machine (UTM). Statistical analysis was performed using one-way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) test (<i>p</i> < 0.05). Results: One-way ANOVA revealed a significant difference (<i>p</i> < 0.001) among the groups. PEEK (1795.7 µε) showed significantly lower values of microstrain compared to zirconia (3110 µε) and PFM crowns (3435.9 µε). In all groups, strain was found to be higher on the buccal aspect, followed by the distal, lingual, and least in the mesial region. Conclusion: Peri-implant strain is influenced by the type of restorative material. PEEK significantly reduced the peri-implant strain relative to zirconia and PFM implant-supported crowns. PEEK may be a more biomechanically favorable material for implant-supported restorations, offering better stress distribution and reducing the risk of excessive peri-implant bone strain. How to cite this article: Kaur K, Sehgal K, Sahore P, <i>et al.</i> Comparative Evaluation of Peri-implant Strain Generated by Implant-supported Crowns Fabricated with Different Restorative Materials: An <i>In Vitro</i> Study. Int J Prosthodont Restor Dent 2025;15(1):20–26.

Authors

Publication Details

Journal
International Journal of Prosthodontics and Restorative Dentistry
Published
2025-03-28
DOI
https://doi.org/10.5005/jp-journals-10019-1487
Citations
1
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
1.79
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Evaluation of Peri-implant Strain Generated by Implant-supported Crowns Fabricated with Different Restorative Materials: An In Vitro Study

Komalpreet Kaur, Shrishti Bhardwaj, Prashant Jindal, Komal Sehgal et al.
1 citations
International Journal of Prosthodontics and Restorative Dentistry
Dental Implant Techniques and Outcomes
1.79
article

Comparative Evaluation of Peri-implant Strain Generated by Implant-supported Crowns Fabricated with Different Restorative Materials: An In Vitro Study

Komalpreet Kaur, Shrishti Bhardwaj, Prashant Jindal, Komal Sehgal, Shefali Singla, Puneet Sahore
article en
1 citations

Abstract

Purpose: To evaluate and compare peri-implant strain generated by polyetheretherketone (PEEK), zirconia, and porcelain-fused-to-metal (PFM) screw- and cement-retained implant-supported crowns using strain gauges. Materials and methods: A 4 × 12 mm implant (Dentium) was placed in a polymethyl methacrylate (PMMA) block. A prefabricated standard abutment was screwed onto the implant and scanned using a lab scanner. Thirty crowns for the three study groups (<i>n</i> = 10 each), namely PEEK, zirconia, and PFM, were fabricated and screwed onto the implant. Four strain gauges were bonded on the test block around the implant neck at buccal, lingual, mesial, and distal locations. An axial load of 250 N was applied in the center of the crown using a universal testing machine (UTM). Statistical analysis was performed using one-way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) test (<i>p</i> < 0.05). Results: One-way ANOVA revealed a significant difference (<i>p</i> < 0.001) among the groups. PEEK (1795.7 µε) showed significantly lower values of microstrain compared to zirconia (3110 µε) and PFM crowns (3435.9 µε). In all groups, strain was found to be higher on the buccal aspect, followed by the distal, lingual, and least in the mesial region. Conclusion: Peri-implant strain is influenced by the type of restorative material. PEEK significantly reduced the peri-implant strain relative to zirconia and PFM implant-supported crowns. PEEK may be a more biomechanically favorable material for implant-supported restorations, offering better stress distribution and reducing the risk of excessive peri-implant bone strain. How to cite this article: Kaur K, Sehgal K, Sahore P, <i>et al.</i> Comparative Evaluation of Peri-implant Strain Generated by Implant-supported Crowns Fabricated with Different Restorative Materials: An <i>In Vitro</i> Study. Int J Prosthodont Restor Dent 2025;15(1):20–26.

International Journal of Prosthodontics and Restorative DentistryVol. 15(1)
Openalex Percentile: Top 18%
Dental Implant Techniques and Outcomes
1.79
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.