Ultra-low limit of detection of a carcinoembryonic antigen fiber sensor based on microfiber

Fiber optic sensors have been widely applied to address issues such as cardiovascular diseases, pathogen detection, and cancer biomarker detection. In this work, an ultra-low limit of detection, high-specificity, and label-free optical fiber biosensor for the detection of carcinoembryonic antigen (CEA) was proposed and experimentally demonstrated. A microfiber interferometer with refractive index sensitivity of up to 1915.955 nm/RIU was employed as the sensor head. The sensitivity of the sensor was further enhanced by the incorporation of molybdenum disulfide (MoS<sub>2</sub>), which facilitated the immobilization of CEA antibodies as specific detection markers on the microfiber surface. Experimental results showed that the proposed sensor achieved a detection limit of 15.86 fg/mL. The sensitivity of the biosensor was 4.727 nm/log(mg/mL). Notably, this biosensor demonstrated excellent specificity and label-free operation and enabled the detection of low-concentration CEA in approximately 15 minutes. The proposed micro fiber CEA sensor provided a highly sensitive and low-cost method for the early diagnosis of cancer.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-04-04
DOI
https://doi.org/10.1364/boe.559885
Citations
2
Primary Topic
Advanced Biosensing Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultra-low limit of detection of a carcinoembryonic antigen fiber sensor based on microfiber

Rongguo Lu, Senyu Wang, Jinlong Wan, Sirong Zhou et al.
2 citations
Biomedical Optics Express
Advanced Biosensing Techniques and Applications
1.61
article

Ultra-low limit of detection of a carcinoembryonic antigen fiber sensor based on microfiber

Rongguo Lu, Senyu Wang, Jinlong Wan, Sirong Zhou, Lulu Cai, Yi Huang, Jianfeng Li, Mingrui Jiang, Hongbo Qiu
article en
2 citations

Abstract

Fiber optic sensors have been widely applied to address issues such as cardiovascular diseases, pathogen detection, and cancer biomarker detection. In this work, an ultra-low limit of detection, high-specificity, and label-free optical fiber biosensor for the detection of carcinoembryonic antigen (CEA) was proposed and experimentally demonstrated. A microfiber interferometer with refractive index sensitivity of up to 1915.955 nm/RIU was employed as the sensor head. The sensitivity of the sensor was further enhanced by the incorporation of molybdenum disulfide (MoS<sub>2</sub>), which facilitated the immobilization of CEA antibodies as specific detection markers on the microfiber surface. Experimental results showed that the proposed sensor achieved a detection limit of 15.86 fg/mL. The sensitivity of the biosensor was 4.727 nm/log(mg/mL). Notably, this biosensor demonstrated excellent specificity and label-free operation and enabled the detection of low-concentration CEA in approximately 15 minutes. The proposed micro fiber CEA sensor provided a highly sensitive and low-cost method for the early diagnosis of cancer.

Biomedical Optics ExpressVol. 16(6)
University of Electronic Science and Technology of China (CN), Chengdu University (CN)
Openalex Percentile: Top 18%
Advanced Biosensing Techniques and Applications
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Ultra-low limit of detection of a carcinoembryonic antigen fiber sensor based on microfiber — Rongguo Lu, Senyu Wang, et al. · Biomedical Optics Express (2025) | TGRS Research Map | TGRS