Experimental Study of the Effect of Wire Fiber Addition on the Mechanical Strength of Preplaced Aggregate Concrete

Preplaced Aggregate Concrete (PAC) is a specialized type of concrete, with low tensile strength, making it prone to brittle failure, used in the construction industry. One effective way to enhance durability and minimize cracking is by incorporating fibers into the mix. This study explores the use of wire fibers, produced by cutting wire ropes into pieces approximately 1 mm in diameter and 60 mm in length. Five different concrete mixtures were tested to evaluate the mechanical strength of PAC and Preplaced Aggregate Wire Fiber Concrete (PAWFC). The wire fiber content varied at 0%, 0.25%, 0.5%, 0.75%, and 1% of the total concrete volume, while the proportions of cement, fine and coarse aggregates, water, and Super Plasticizer (SP) remained constant. A mortar mix with a cement-to-sand ratio of 1 and a water-to-cement ratio of 0.45 was used. The mechanical properties, including compressive strength, tensile strength, and modulus of rupture were assessed following the ASTM standards. The results showed that adding wire fiber significantly improved the mechanical strength of PAWFC. Specifically, the optimum 1% wire fiber addition increased compressive strength by 11.23%, tensile strength by 36.85%, and modulus of rupture by 17.23%.

Authors

Publication Details

Journal
Engineering Technology & Applied Science Research
Published
2025-04-03
DOI
https://doi.org/10.48084/etasr.10028
Primary Topic
Innovative concrete reinforcement materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study of the Effect of Wire Fiber Addition on the Mechanical Strength of Preplaced Aggregate Concrete

Jauhar Fajrin, Ni Nyoman Kencanawati, Buan Anshari, Ngudiyono Ngudiyono et al.
Engineering Technology & Applied Science Research
Innovative concrete reinforcement materials
article

Experimental Study of the Effect of Wire Fiber Addition on the Mechanical Strength of Preplaced Aggregate Concrete

Jauhar Fajrin, Ni Nyoman Kencanawati, Buan Anshari, Ngudiyono Ngudiyono, M. Yani Aqriansyah, Akmaluddin Akmaluddin
article en

Abstract

Preplaced Aggregate Concrete (PAC) is a specialized type of concrete, with low tensile strength, making it prone to brittle failure, used in the construction industry. One effective way to enhance durability and minimize cracking is by incorporating fibers into the mix. This study explores the use of wire fibers, produced by cutting wire ropes into pieces approximately 1 mm in diameter and 60 mm in length. Five different concrete mixtures were tested to evaluate the mechanical strength of PAC and Preplaced Aggregate Wire Fiber Concrete (PAWFC). The wire fiber content varied at 0%, 0.25%, 0.5%, 0.75%, and 1% of the total concrete volume, while the proportions of cement, fine and coarse aggregates, water, and Super Plasticizer (SP) remained constant. A mortar mix with a cement-to-sand ratio of 1 and a water-to-cement ratio of 0.45 was used. The mechanical properties, including compressive strength, tensile strength, and modulus of rupture were assessed following the ASTM standards. The results showed that adding wire fiber significantly improved the mechanical strength of PAWFC. Specifically, the optimum 1% wire fiber addition increased compressive strength by 11.23%, tensile strength by 36.85%, and modulus of rupture by 17.23%.

Engineering Technology & Applied Science ResearchVol. 15(2)
Openalex Percentile: Top 93%
Innovative concrete reinforcement materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental Study of the Effect of Wire Fiber Addition on the Mechanical Strength of Preplaced Aggregate Concrete — Jauhar Fajrin, Ni Nyoman Kencanawati, et al. · Engineering Technology & Applied Science Research (2025) | TGRS Research Map | TGRS