Analysis of Pharmaceutical Active Compounds in Complex Water Samples: Sample Filtration as an Option

Sample pretreatment is one of the most important steps in guaranteeing the success of a chromatographic analysis. The selected methodology must ensure simultaneously that a sample is "clean" enough for analysis and that the target analytes are not removed in the process. This can be especially difficult when working with complex matrices such as natural waters and wastewater. For pharmaceutical active compounds (PhACs) analysis by solid-phase extraction (SPE) followed by ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS), and due to the high level of organic matter in wastewater, the water samples are filtered consecutively through three filters, a paper filter, a glass microfiber filter of 1 µm, and a Nylon filter of 0.45 µm. This filtration allows the sample's passage through the SPE cartridge to be faster, and there is no cartridge clogging, allowing for greater efficiency in the adsorption process. The big question is whether the PhACs are eliminated during filtration, since they may be adsorbed to organic matter. This work aimed to determine if the best approach for quantifying PhACs in wastewater and surface waters would be to filter them prior or to perform SPE directly. Both approaches analyzed a total of 26 PhACs. Turbidity (TUR) and permanganate index (PI) were determined, and their values were high for samples with a high organic matter content. A statistical analysis was performed to determine the best approach to treat these water samples and whether any correlation existed between PhAC concentrations, PI, and TUR. The PhAC quantification shows a positive correlation with TUR and a negative correlation with PI for most of the target PhACs. However, there are not significantly different results for filtered and not-filtered wastewater samples.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2025-04-03
DOI
https://doi.org/10.3390/molecules30071609
Citations
1
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Pharmaceutical Active Compounds in Complex Water Samples: Sample Filtration as an Option

Cristina Almeida, Rui Neves Carneiro, João A. Rodrigues, Vítor Vale Cardoso et al.
1 citations
Molecules
Analytical chemistry methods development
0.75
article

Analysis of Pharmaceutical Active Compounds in Complex Water Samples: Sample Filtration as an Option

Cristina Almeida, Rui Neves Carneiro, João A. Rodrigues, Vítor Vale Cardoso, Sofia Silva
article en
1 citations

Abstract

Sample pretreatment is one of the most important steps in guaranteeing the success of a chromatographic analysis. The selected methodology must ensure simultaneously that a sample is "clean" enough for analysis and that the target analytes are not removed in the process. This can be especially difficult when working with complex matrices such as natural waters and wastewater. For pharmaceutical active compounds (PhACs) analysis by solid-phase extraction (SPE) followed by ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS), and due to the high level of organic matter in wastewater, the water samples are filtered consecutively through three filters, a paper filter, a glass microfiber filter of 1 µm, and a Nylon filter of 0.45 µm. This filtration allows the sample's passage through the SPE cartridge to be faster, and there is no cartridge clogging, allowing for greater efficiency in the adsorption process. The big question is whether the PhACs are eliminated during filtration, since they may be adsorbed to organic matter. This work aimed to determine if the best approach for quantifying PhACs in wastewater and surface waters would be to filter them prior or to perform SPE directly. Both approaches analyzed a total of 26 PhACs. Turbidity (TUR) and permanganate index (PI) were determined, and their values were high for samples with a high organic matter content. A statistical analysis was performed to determine the best approach to treat these water samples and whether any correlation existed between PhAC concentrations, PI, and TUR. The PhAC quantification shows a positive correlation with TUR and a negative correlation with PI for most of the target PhACs. However, there are not significantly different results for filtered and not-filtered wastewater samples.

MoleculesVol. 30(7)
University of Lisbon (PT), Águas de Portugal (Portugal) (PT), University of Aveiro (PT)
Clean water and sanitation
Openalex Percentile: Top 34%
Analytical chemistry methods development
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.